3.4.6 Host
–
J1
The host port is for upgrading the sweep software.
IF J1 IS CONNECTED TO A PC
THE PROGRAMMABLE SWEEP WILL AUTOMATICLY GO IN TO DOWNLOAD
MODE.
Figure 3-7, Host Port
3.4.7 Output - J3
Connection of the sweep generator to the EB Source is shown in Figure 3-8, 3-9, 3-
10, 3-11. The horizontal and lateral coils should be brought out of the tank by way of
a feedthrough and connected to pins 1, 2, 3 of J3 on the Sweep Module as shown.
The interconnecting wire must be capable of passing a minimum of two amperes.
The return wire is shared by both longitudinal and lateral coils. The sweep voltage is
grounded inside the sweeper. However, you should connect the return wire to ground
at the EB source end. To leave the return wire ungrounded could damage the
sweeper. Normally one side of each coil is connected to ground at the electron beam
source. The return wire is connected to the same spot inside the tank. The Lat and
Long direction can be change in the
Config System
menu by pressing
Lat Flip
and
or
Long Flip
.
Figure 3-8, Telemark standard Coil Wire Reference Code