Programmable Sweep Instruction Manual
INSTALLATION
telemark.com
20 of 58
Rev 1.0.0
3.4.3 Mains Connection
The mains connection is designed for a mains cable which contains IEC 320
connector on the device side. A mains cable is supplied with the device. If the plug is
not compatible with your wall socket, you should replace it with a suitable mains
cable:
Three-conductor cable with protective ground
Conductor cross-section 3x1.5 mm
2
or larger
Figure 3-4, Three-conductor cable with protective ground (example)
Mains power.
Improperly grounded devices can be extremely dangerous in the event
of a fault. Use three-wire mains or extension cables with protective
ground only. Plug the mains cable into wall sockets with protective
ground only.
1. Connect the appliance connector of the mains cord with the mains connection of
the device
2. Connect the plug of the mains cable with the wall socket
Note:
If the device is installed in a switching cabinet, the mains power can be supplied via a
switchable central power distributor.
3.4.4 Grounding
Grounding screw (Fig. 3-3, the reference F) should be used to connect the
Programmable Sweep with the main grounding system in which it operates. It is
recommended to use a cable with a minimum section of 2.5 mm
2
DANGER
!