R305 AT Commands
©2011 Telegesis (UK) Ltd
- 88 -
AT Command Manual (Rev 3.05)
S44
– Profile ID for xCASTs (volatile)
Description
The profile ID for all messages.
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Storage
Volatile
Parameters
XXXX
The profile ID of any xCAST message
Factory Default
Defined in S45
SW release
R300
S45
– Initial Setting of S44
Description
The initial setting of S44 stored in non
volatile memory
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
After Soft or Hard Reset
Storage
Non-Volatile
Parameters
XXXX
The profile ID of any xCAST message
Factory Default
C091
SW release
R300
S46
– Start-up Functionality 32-bit number
Description
Volatile 32-bit register which can be used by
some of the build in functionality
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Storage
Volatile
Parameters
XXXXXXXX
Factory Default
00000000
SW release
R303
– upgraded to 32-bit