R305 AT Commands
©2011 Telegesis (UK) Ltd
- 77 -
AT Command Manual (Rev 3.05)
S2D
–Timer/Counter 2
Description
A multipurpose Timer/Counter whose
functionality is defined by S2E
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Storage
Non-Volatile
Parameters
XXXX
A 16-bit hexadecimal number representing a
threshold for either a timer or counter event to be
triggered. When reading this register the threshold
rather than the actual timer/counter value is
displayed.
If set to 0 the corresponding functionality is
disabled.
Factory Default
00F4 (1 min 1s interval)
SW release
R300
S2E
– Functionality For Timer/Counter 2
Description
Defines the functionality for Timer/Counter 2
events.
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Storage
Non-Volatile
Parameters
XXXX
If set to 0 the functionality is disabled. Please see
section 5 for a list of the functionalities.
Factory Default
8014 (leave network if I am alone)
SW release
R300