For the installation wiring of the relay contacts, SwitchBox and power supply of
the device, use commercially available telecommunication cables.
Please note that in order to meet general safety provision and to avoid interfer-
ence influences, the low-current lines must be routed separately from power
lines.
Observe a minimum distance of 10 cm between both types of lines. If one of
the connected lines is routed out-of-doors, you will have to provide sufficient
lightning protection.
Lines types that can be used
▪
Telecommunication indoor cable
– J-Y(ST)-Y 2 x 2 x 0.6
– J-Y(ST)-Y 2 x 2 x 0.8
– J-Y(ST)-Y 4 x 2 x 0.6
– J-Y(ST)-Y 4 x 2 x 0.8
▪
Bell sheathed cable
– YR 4 x 0.8
▪
Telecommunications cable
– A-2Y(L)2Y 4 x 2 x 0.8
Maximum cable lengths for connection to door opener
Wire diameter
0.8 mm
0.6 mm
Ranges for door opener operation from an ex-
ternal bell transformer to door opener (max-
imum current consumption 1A alternating
voltage)
12 V
16 V
20 V
24 V
38 m
76 m
115 m
177 m
17 m
34 m
51 m
78 m