DM720 Integrated Positioning Camera
Before using the product, please read this manual carefully.
Ⅰ
Страница 1: ...DM720 Integrated Positioning Camera Before using the product please read this manual carefully...
Страница 2: ...the user s authority to operate the equipment under CE and FCC rules Precautions 1 Only qualified and experienced person can carry on this installation 2 Always conform to national and local safety co...
Страница 3: ...2 DisplayConfiguration 13 4 3 Change Password 14 4 4 Language Select 15 4 5 Factory Default 15 4 6 System Restart 15 4 7 About 15 5 Lens Parameters 17 5 1 Zooming Speed 17 5 2 MaxDigital Zoom 17 5 3 F...
Страница 4: ...ing 24 8 1 Presets Setup 24 8 2 Sequence Setup 24 8 3 Pattern Setup 25 8 4 Autoscan Setup 26 8 5 Regions Setup 27 8 6 TimeAction 28 8 7 IdleAction 28 9 Privacy Masking 29 Appendix I DIP Switch Jumper...
Страница 5: ...provide you wide view and image capture and multi protocol options can make it integrate toyour existing system easily For maintenance free purpose IP66 short circuit protection overheat protection ov...
Страница 6: ...our main kinds of installation are available for integrated positioning system 1 Wall Mount 2 Corner Mount 3 Pole Mount 4 Pedestal Mount NOTE Installation site should be able to bear at least 4 times...
Страница 7: ...3 2 2 Installation Tools Common installation tools are listed in following pictures Drill sleeve for M8 screw Inner hexagon wrench for M8 screw Cross head screw driver Shift wrench...
Страница 8: ...t adapter to the 4 M8 screws on bracket route the control cable power cable and video cable through the cable hole and tighten the 4 M8 flat washers spring washers and nuts The last step is to route w...
Страница 9: ...crew and uncap the mount cover Aim the 4 holes on bracket adapter to the 4 M 8 screws on bracket route the control cable power cable and video cable through the cable hole and tighten the 4 M8 flat wa...
Страница 10: ...es on bracket adapter to the 4 M 8 screws on bracket route the control cable power cable and video cable through the cable hole and tighten the 4 M8 flat washers spring washers and nuts The last step...
Страница 11: ...screws on the flange route the control cable power cable and videocable through the cable hole and tighten the 4 M8 flat washers spring washers and nuts The last step is to route wires and cables thro...
Страница 12: ...2 7 Connections n Connections for using RS 485 control C O M1 Power cable 24V Video cable 75 ohm coaxial cable Video switching matrix Monitor System controller RS485A B Communication cable Video outp...
Страница 13: ...ntrol Power cable 24V Power cable 24V video cable 75 ohm coaxial cable video cable 75 ohm coaxial cable Communication cable Communication cable Coaxial convertor Video output Video input Monitor or vi...
Страница 14: ...o the char acter you want to change and directly repeat step 4 l Clear a character Switch the character to Symbol and then position the character you want to delete finally move the joystick up or dow...
Страница 15: ...0 Exit Lens Parameters 1 Zooming Speed High low 2 Max Digital Zoom Off 3 Focus Limit 30cm 4 Vibration Correction Off 5 Iris ALC Value 106 6 Iris PLC Value 016 7 Auto Recovery 8 Color Mono Mode 9 Back...
Страница 16: ...d for the Enter S N setting 3 Move the joystick up or down to select the figure and move it to the left to save the setting 4 Move the joystick to the left or right to quit this editing 5 Select BACK...
Страница 17: ...s the region title for the region mode settings The following settings are available for each title OFF The title is not displayed when enabled ON The title is displayed after activation 2s 60s The ti...
Страница 18: ...ry to enter again in the same way otherwise you can not access to OSD menu Password change succeed Password not match Error Password 6 Set new password as the following submenu ap pears on the screen...
Страница 19: ...N A Focus Min Limit 30CM Backlight Mode Off Iris ALCvalue 084 Backlight Value N A Iris PLCvalue 016 Auto Stop Timer Off Preset Freeze Off Speed Magnifier X01 Line Lock Phase Off Proportional PT ON Exp...
Страница 20: ...rried out Move the joystick to select ABOUT the following pic ture will be displayed on the screen Camera S N 0000000000000000 Camera ID 0001 SOFT Baud Rate 4800bps Protocol FACTORY Model DM729 Camera...
Страница 21: ...The value ranges from 000 to 255 Default value is illustrated as below 22X color camera 066 23X color mono camera 084 different camera has different ALC default value NOTE Changing default value is s...
Страница 22: ...automatically switches be tween color and monochrome mode in accordance with the environment illumination Four settings are available Setting Description Auto The dome will automatically change modes...
Страница 23: ...riority Values are F1 6 F2 2 F3 2 F4 4 F6 4 F8 8 F12 F17 F24 F34 AGC Set Auto gain control in priority Values are 0dB 6dB 12dB 18dB 24dB 30dB Higher dB value makes image brighter NOTE Only if Exposure...
Страница 24: ...nt backlight compensation grade Higher the number brighter the im age is Backlight Mode 1 Backlight Mode OFF 2 Backlight Value N A 3 WDR2 Invalid 3 Back 0 Exit Mode Normal WDR Off N A N A Normal 000 2...
Страница 25: ...25 270 315 N 0 Horizontal 0 360 Auto Stop Timer For some particular protocols the camera does not stop moving even if no operation comes from the controller But this function enables the camera to sto...
Страница 26: ...t observation position as the original direction Define the Origin of 180 180 Set the start end observation position of 180 180 mode For example l Move to a position and call preset 1 to confirm Move...
Страница 27: ...the level is the highest one is 005 more sensitive it will be Motion Linkage When motion detect is ON and there is a moving object dome will perform the prepared link age function such as preset autos...
Страница 28: ...ich can be displayed on the screen Please refer to page 11 in details 3 Set New Preset This allows you to set the new preset The following picture will pop up as you tilt the joystick Move to the desi...
Страница 29: ...lect Save to save the sequence select Discard to quit without saving NOTE When a preset s dwell time is set 0 system will skip that preset System will consider preset 0 as the end of a sequence Deleti...
Страница 30: ...up Autoscan Setup 1 Autoscan Number 001 2 Title 3 Set Left Limit 4 Set Right Limit 5 Defaul Speed 255 6 Run Continuously 7 Delete Current 8 Back 0 Exit This function allows you to set the left and rig...
Страница 31: ...between two sites User can edit a title for a REGION E g Dangerous area Whenever the camera moves into the region the title will display on the screen to alert the user l Up to four regions can be set...
Страница 32: ...tion Autoscan 1 4 Enable Panning function NOTE The specified time can not be overlapped Otherwise the assigned Timer Running functions are ineffective Timer Running function is prior to Auto Action fu...
Страница 33: ...ght The follow ing picture will display on the screen 3 Move the joystick to move the mask to the position to be masked and then call PRESET 1 to confirm call PRESET 2 to cancel The following picture...
Страница 34: ...DIP switches 1 Remove the plug from the left cover It is not neces sary to remove the pan and tilt cover 2 Set the baud rate and receiver address 3 Replace the plug Protocol and Baud rate setting SW2...
Страница 35: ...the SW1 to 0 all OFF the system will react to any command for any ID NOTE Debug ID only works with Factory protocol l Broadcast ID When a command is sent to broad cast ID all systems connected to the...
Страница 36: ...32 O N ID Sw itc h N um b e r 1 2 3 4 5 6 7 8 O N ID Sw itc h N um b e r 1 2 3 4 5 6 7 8...
Страница 37: ...6 3 16 4 16 5 16 6 16 7 16 8 16 9 17 0 17 1 17 2 17 3 17 4 17 5 ID Sw itc h N um b e r 1 2 3 4 5 6 7 8 O N 17 6 17 7 17 8 17 9 18 0 18 1 18 2 18 3 18 4 18 5 18 6 18 7 18 8 18 9 19 0 19 1 19 2 19 3 19...
Страница 38: ...N 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 Switc h Number ID Progra m mab le Ad dress 255 1 2 3 4 5 6...
Страница 39: ...daisy chain con nection between the equipment There must be ter mination resistors with 120 Ohm impedance at both ends of the connection refer to following pictures Please refer to below picture for s...
Страница 40: ...distributor can change the star configuration connection to the mode of con nection stipulated in the RS485 standards The new connection achieves reliable data transmission refer to following picture...
Страница 41: ...tion extra strong light ning proof equipment must be installed Take the building lightning proof requirements into ac count to design the lightning proof and grounding of outdoor equipment and cable l...
Страница 42: ...n 4 Check the municipal power supply The red LED on the connection board is lit 1 The main controlling board is malfunction 2 Please contact the supplier for replacement of the main controlling board...
Страница 43: ...uese Italian Polish Russian Chinese l 220 presets with title l 4 tours with up to 32 presets each l 4 patterns with PTZ routine recording time is no less than 180 seconds l 4 auto pannings l 8 schedul...
Страница 44: ...000sec 1 1 1 10 000sec Iris Auto Manual Back Light Compensation On Off Lens Aperture stop F 1 6 3 8 Focal length f 3 4 91mm Viewing angle 2 2 54 2 Viewing angle 1 7 57 8 Aperture stop F 1 6 4 5 Focal...