WorkHorse H-ADCP Operation Manual
May
2015
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Page 77
Use the old cut-off Molex connector as a reference in addition to the schematic diagram
when installing the new Molex connector. Each wire should have a corresponding J1 pin
number tag.
15. After all the pins for the connector are installed, use a multi-meter to confirm that the connector
has been wired properly by performing an end-to-end continuity check.
16. Use the black lacing cord to bind the connector wires together. The lacing is applied by wrapping
it around the wire bundle approximately four times and then tying it securely with a square knot.
Each wrap on the wire bundle should be spaced approximately 3-inches apart. This will prevent
the wires from “bird caging” out and getting caught between the end-cap and pressure case O-
ring.
Wiring Diagrams
Figure 37.
End-Cap Connector Wiring – H-ADCP