WorkHorse H-ADCP Operation Manual
May
2015
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Page 235
:BE, +17, +18, -20,A
:WD, +0.00, +0.00, +0.00, 20.00, 0.00
:BD, -0.02, -0.03, +0.02, 7.13, 0.21
PD8 ASCII Output
The H-ADCP sends this data format only when the PD8 command is used. PD8 outputs ensemble data as
formatted text. A new-line character terminates each line. Two new-line characters terminate an ensem-
ble.
PD8 data is only for serial output. If you select PD8 and set the CF command to CFxxx01 (recorder on),
the H-ADCP will output PD8 ASCII data out the serial port and record PD0 data to the recorder card. You
can then use the PD0 data to troubleshoot any setup problems with the H-ADCP.
1997/02/28 11:16:50.07 00001
Hdg: 209.1 Pitch: 9.6 Roll: -9.1
Temp: 22.8 SoS: 1529 BIT: 00
Bin Dir Mag E/W N/S Vert Err Echo1 Echo2 Echo3 Echo4
1 -- -- -32768 -32768 -32768 -32768 43 49 46 43
2 -- -- -32768 -32768 -32768 -32768 44 41 45 44
3 -- -- -32768 -32768 -32768 -32768 43 41 45 43
4 -- -- -32768 -32768 -32768 -32768 43 41 46 43
5 -- -- -32768 -32768 -32768 -32768 43 41 45 43
6 -- -- -32768 -32768 -32768 -32768 42 41 46 43
7 -- -- -32768 -32768 -32768 -32768 43 42 46 43
8 -- -- -32768 -32768 -32768 -32768 43 40 46 43
9 -- -- -32768 -32768 -32768 -32768 43 41 45 44
10 -- -- -32768 -32768 -32768 -32768 44 41 46 44
If all beams have good data, then direction and magnitude are output as well.
PD8 output data format can not be recorded – it must be output through the serial port only.
Do not use this output data format for a self-contained deployment.