TT – Set Real-Time Clock (Y2k Compliant)
Purpose
Sets the H-ADCP’s internal real-time clock.
Format
TTccyy/mm/dd, hh:mm:ss
Range
cc
= century 19 to 20
yy
= year
00 to 99
mm
= month 01 to 12
dd
= day
01 to 31
hh
= hour
00 to 23
mm
= minute 00 to 59
ss
= second 00 to 59
Recommended Setting.
Set using
BBTalk
or
SurfaceView.
Example
TT2000/06/17, 13:15:00 sets the real-time clock to 1:15:00 pm, June 17, 2000.
1. When the H-ADCP receives the carriage return after the TS-command, it enters the new time
into the real-time clock and sets hundredths of seconds to zero.
2. If the entry is not valid, the H-ADCP sends an error message and does not update the real-