May
2015
WorkHorse H-ADCP Operation Manual
Page 158
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
PS0 – System Configuration
PS0 sends the H-ADCP hardware/firmware information. For example, the output may look like this:
>ps0
Instrument S/N: 0
Frequency: 307200 HZ
Configuration: 4 BEAM, JANUS
Match Layer: 10
Beam Angle: 20 DEGREES
Beam Pattern: CONVEX
Orientation: DOWN
Sensor(s): HEADING TILT 1 TILT 2 DEPTH TEMPERATURE PRESSURE
Pressure Sens Coefficients:
c3 = +0.00
c2 = +0.00
c1 = -2.500000E-03
Offset = +0.00
Temp Sens Offset: -0.20 degrees C
CPU Firmware: 16.xx
Boot Code Ver: Required: 1.13 Actual: 1.13
DEMOD #1 Ver: ad48, Type: 1f
DEMOD #2 Ver: ad48, Type: 1f
PWRTIMG Ver: 85d3, Type: 6
Board Serial Number Data:
08 00 00 02 C9 20 A7 09 CPU727-2000-00H
4D 00 00 00 D4 97 37 09 PIO727-3000-03C
>
PS3 – Instrument Transformation Matrix
PS3 sends information about the transducer beams. The H-ADCP uses this information in its coordinate-
transformation calculations; for example, the output may look like this:
ps3
Beam Width: 3.7 degrees
Beam Elevation Azimuth
1 -70.14 269.72
2 -70.10 89.72
3 -69.99 0.28
4 -70.01 180.28
Beam Directional Matrix (Down):
0.3399 0.0017 0.9405 0.2414
-0.3405 -0.0017 0.9403 0.2410
-0.0017 -0.3424 0.9396 -0.2411
0.0017 0.3420 0.9398 -0.2415
Instrument Transformation Matrix (Down): Q14:
1.4691 -1.4705 0.0078 -0.0067 24069 -24092 127 -109
-0.0068 0.0078 -1.4618 1.4606 -111 127 -23950 23930
0.2663 0.2657 0.2657 0.2661 4363 4354 4353 4359
1.0367 1.0350 -1.0359 -1.0374 16985 16957 -16972 -16996
Beam Angle Corrections Are Loaded.
>
If the H-ADCP needs beam angle corrections, a TRDI calibrated beam angle matrix is loaded into the in-
strument. This is done when the instrument is manufactured. For more details, request a copy of the
H-ADCP Coordinate Transformation booklet (available for download at
).
The output may look like this for an H-ADCP.
Beam Width: 3.7 degrees
Instrument Transformation Matrix (Down): Q14:
-1.1831 1.1831 0.0000 0.0000 -19384 19384 0 0
-0.3430 -0.3430 -0.3784 0.0000 -5619 -5619 -6199 0
0.0000 0.0000 0.0000 0.0000 0 0 0 0
0.7278 0.7278 -1.3192 0.0000 11924 11924 -21613 0
Beam Angle Corrections Are Loaded.