May
2015
WorkHorse H-ADCP Operation Manual
Page 108
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Power
H-ADCP 300
H-ADCP 600
H-ADCP-N 300
DC Input
20 to 50 VDC external power supply
Transmit
60W @ 48V (600kHz), 190W @ 48V (300kHz)
Communications
H-ADCP 300
H-ADCP 600
H-ADCP-N 300
Serial port
Selectable by switch for RS-232 or RS-422.
ASCII or binary output at 1200 to 115,200 baud.
Optional Internal memory
Optional memory card. Two PCMCIA memory card slots are available. The maximum
memory for each slot is 2GB, with the total memory capacity not to exceed 4GB.
Sensors
H-ADCP 300
H-ADCP 600
H-ADCP-N 300
Temperature
Range -5° to 45° C, Precision ±0.4° C, Resolution 0.01°
Compass
(1)
Type flux gate, Accuracy ±2°, Precision
±
0.50, Resolution 0.01°, Max tilt
±
15
°
Optional Pressure Sensor
(2)
Short-term uncertainty ±0.1%, Max. drift ±0.25%
1.
@ 60° magnetic dip angle, 0.5G total field. Includes built-in field calibration procedure.
Compass uncertainty is for tilts less than 15°.
2.
A 50m pressure sensor is standard. 100m and 200m are available if required.
Outline Installation Drawings
The following drawings show the standard H-ADCP Monitor, Sentinel, Mariner, and Mariner Deck Box
dimensions and weights.
Table 10:
Outline Installation Drawings
Description
Drawing #
600 kHz H-ADCP
967-1004
300 kHz H-ADCP
967-1015
300 kHz Narrow Beam Width H-ADCP (early builds)
967-6043
300 kHz Narrow Beam Width H-ADCP (one piece housing)
967-6095
300 kHz Narrow Beam Width H-ADCP (two piece housing)
967-6096
Outline Installation Drawings are subject to change without notice. Verify you have the latest
version of the drawing by contacting TRDI before building mounts or other hardware.