Operating Instructions
Teledyne API - Model T200H/T200M Operation Manual
170
4.15.2.6. Remote Access by Modem
The T200H/M can be connected to a modem for remote access. This requires a cable
between the analyzer’s COM port and the modem, typically a DB-9F to DB-25M cable
(available from Teledyne API with part number WR0000024).
Once the cable has been connected, check to make sure the DTE-DCE is in the correct
position. Also make sure the T200H/M COM port is set for a baud rate that is
compatible with the modem, which needs to operate with an 8-bit word length with one
stop bit.
The first step is to turn on the
MODEM ENABLE
communication mode (Mode 64).
Once this is completed, the appropriate setup command line for your modem can be
entered into the analyzer. The default setting for this feature is
AT Y0 &D0 &H0 &I0 S0=2 &B0 &N6 &M0 E0 Q1 &W0
This string can be altered to match your modem’s initialization and can be up to 100
characters long.
Note
If Hessen Protocol Mode is active for a com port, operation via a modem is not
available on that port.
To change this setting press:
SETUP X.X
SECONDARY SETUP MENU
COMM
VARS DIAG ALRM
EXIT
SETUP X.X
PRIMARY SETUP MENU
CFG DAS
RNGE
PASS CLK
MORE
EXIT
SAMPLE A1:NXCNC1=100PPM NOX=XXX.X
< TST TST > CAL
SETUP
SETUP X.X
COM1 MODEM INIT:AT Y
∅
&D
∅
&H
<SET SET>
EDIT
EXIT
S
ETUP X.X COM1 MODEM INIT:
[A]
T Y
∅
&D
∅
&H
<CH CH> INS DEL [A]
ENTR
EXIT
SETUP X.X
COM1 MODE:0
SET>
EDIT
EXIT
SETUP X.X COM1 BAUD RATE:19200
<SET
SET>
EDIT
EXIT
ENTR
accepts the
new string and returns
to the previous menu.
EXIT
ignores the new
string and returns to
the previous menu.
The
<CH
and
CH>
buttons
move the
[ ]
cursor left and
right along the text string
INS
inserts a
character before
the cursor location.
Press the
[?]
key
repeatedly to cycle through the
available character set:
0-9
A-Z
space ’ ~ !
# $ % ^ & * ( ) - _ =
+[ ] { } < >\ | ; : , . / ?
DEL
deletes a
character at the
cursor location.
SETUP X.X
COMMUNICATIONS MENU
ID INET
COM1
COM2
EXIT
Select which
COM Port is
tested
EXIT returns
to the
previous
menu
07270D DCN7141
Содержание T200H
Страница 2: ......
Страница 4: ...Teledyne API Model T200H T200M Operation Manual ii This page intentionally left blank 07270D DCN7141 ...
Страница 8: ...Teledyne API Model T200H T200M Operation Manual vi This page intentionally left blank 07270D DCN7141 ...
Страница 10: ...Teledyne API Model T200H T200M Operation Manual viii This page intentionally left blank 07270D DCN7141 ...
Страница 12: ...Teledyne API Model T200H T200M Operation Manual x This page intentionally left blank 07270D DCN7141 ...
Страница 344: ...This page intentionally left blank B 2 07270D DCN7141 ...
Страница 353: ...APPENDIX D 07270D DCN7141 07270D DCN7141 D 1 D 1 ...