2.12.6 Outgoing Frame Settings
Before selecting Outgoing Frame Settings, select the Types Of Frames and the
Frame Number on which to inject an error. Then check
Outgoing
Frame
in the
Generate
Error
On
area and then the enabled
Settings
button to display the Outgoing Frame
Setting dialog.
Figure 2.214: Outgoing Frame Setting Dialog
Frame Type Error
Check this to introduce a frame type error.
Drop Link for
Check this to drop link for specified duration.
Remove Frame from sequence
Check this to remove frame from sequence.
Delay in sending frame
Check this to delay sending frame and enter a value for the delay.
Additionally check:
No WTRM
Code Violation on SATA primitive
Disparity error on SATA primitive
Ignore XRDY/RRDY sequence
Delay in HOLD response (in sending HOLDA)
Frame Length Error
Check
Frame
Length
Error,
choose the type of error to introduce and click
OK
.
Code violation and Disparity error
Check these and specify DWORD offset and the number of error DWORDs.