Sierra M6
‐
2 SAS/SATA Protocol Analyzer User Manual
185
Target and Device Emulation
Teledyne LeCroy
Figure 2.198: SAS: Target Emulation Project Pages Tab
The Target Emulator pages open with default settings for each page. To change settings
for your application:
1. Select a page in the Supported Pages box and set values for each of the enabled
(white) Value fields.
2. Enter values for Density Code, Medium Type, and Device Specific Parameter for the
target emulator.
3. Check
SSP
or
SMP
to specify the protocol to support.
4. To reset the pages to the default settings, click the
Default
Settings
button.
5. To use a previously defined Target, click the
Import
button and choose a previously
defined Device Identifier *.saf file.
Note:
Clicking the
Import
button on any of the Target Emulation dialogs sets all the parameters for the
current emulation, including User
‐
Defined Commands.