B.5
SeaBat T-Series Subsea Installation
B.5.1 Subsea Sonar Processor (PN 1009483)
Table 14: SSP Technical Specifications
Specification
Value
Power requirements
27
22-60VDC
Power consumption
28
T20-S: Average 110W. Peak 370W.
T50-S: Average 130W. Peak 390W.
Data communication
Gigabit Ethernet
Dimensions
(excl. connectors)
Length:
494mm
Diameter: 174mm
Weight (excl. cables)
Air:
24.4kg
Water: 10.2kg
Temperature
Operating:-2° to +36°C (submerged)
Storage: -30° to +70°C
The SSP pressure housing should be mounted in a convenient location within easy
reach of the projector/receiver to SSP cables.
The SSP housing may be secured with straps.
CAUTION
The blue transport bumpers should be removed prior to installation of the SSP.
The SSP should be mounted horizontally with a free flow of water around the unit.
CAUTION
DO NOT OPEN the pressure housing. The SSP pressure housing is nitrogen-filled
and sealed.
B.5.2 EM7219-1 Receiver Unit (PN 85002536) – T20
Table 15: EM7219-1 Receiver Unit Technical Specifications
Specification Value
Material
Titanium (grade 2) lid
Polyurethane acoustic window
Dimensions
Height
123.2mm
Length:
254.0mm
Depth:
102.0mm
Weight
Air:
5.0kg
Water:
2.2kg
Temperature
Operating: -2° to +36°C
Storage: -30° to +70°C
The EM7219-1 receiver unit mounts to the vessel or mounting bracket with four M8
screws already in place in the receiver.
For ease of mounting, the ends of the housing are labeled P and S for Port and
Starboard, respectively. The connector is placed on the port side.
CAUTION
Ensure free access to water inlet holes (on starboard side) for pressure equalization.
27
36-54VDC for IDH configurations.
28
T20-S IDH: Average 150W. Peak 410W. T50-S IDH: Average 200W. Peak 460W.