32
Configuration
Teledyne PDS - Teledyne PDS, T20-P and POS MV Quick Setup
Figure 3-24
Motion Input/Output set-up
The communication settings as set must also set in the SUI. Refer to
the SUI’s section ‘Roll Stabilization
’ on page 19.
3.5.5 Position
It is recommended using the Ethernet connection to output position and
motion data to Teledyne PDS or the SUI instead as serial connections.
(When serial connections are used COM 3, COM 4 and COM 5 port are
configured to output these messages serially.)
3.5.6 Ethernet Output
To switch on the Ethernet output select from the POSView menu bar
L
ogging
>Ethernet Realtime…
Figure 3-25
Ethernet Realtime
The following messages must be enabled:
3
-
Primary GPS Data
10
-
General Status and fault Detection
12
-
Auxiliary 1 GPS Data
20
-
In Solution status