Teledyne PDS - Teledyne PDS, T20-P and POS MV Quick Setup
Configuration
27
The surveyor can measure the IMU roll/pitch and heading offsets in the
vessel frame. When the
button is pressed the
measurement is converted to the IMU frame and filled in automatically in
the ‘IMU Frame w.r.t. Ref. frame’ box.( C )
The reference point of the POS MV Ethernet 102 output message
(containing position and motion data) is the defined ‘sensor 1’ offset of the
sensor mounting tab.
Leave the sensor 1 offset to zero (0)!! On this way the earlier chosen
reference point (usually the IMU) is the reference point for the 102
Ethernet output messages. In Teledyne PDS it is possible to use this
(IMU) also as reference point. (Otherwise the Sensor 1 reference
must be used as reference in Teledyne PDS)
Figure 3-14
Keep Ref. to Sensor 1 values zero
3.5.3 Timing
The POS MV must be configured to output a time message.
It is possible to output a time message by Ethernet connection or serially.
3.5.3.1 Serial Time Message Output.
See Figure 3-15. Select from the POSView menu bar
Settings>Installation>Tags, Multipath & AutoStart..