Teledyne PDS - Teledyne PDS, T20-P and POS MV Quick Setup
Configuration
25
Figure 3-9
Connect with POS MV
3.5.2 Installation settings
Next step is to setup the installation parameters.
Select in POSView ‘
Settings
’ ‘
Installation
’ ‘
Lever Arms & Mounting
’
Figure 3-10
Lever Arms & Mounting
Choose a reference point on the vessel and measure the X,Y,Z offsets of
the IMU and Primary GPS (ANT1 on the POS MV) to this reference point.
The position as output by the POS MV is with respect to this chosen
reference point. It is easy to choose the IMU as reference point. The
reference point on the IMU is marked with a sticker on the IMU.
Figure 3-11
IMU reference point
BE AWARE OF THE USED CONVETION FOR THE POS MV
INSTALLTION LEVER ARMS & MOUNTING. (Different convention is
used as used by Teledyne PDS).
See Figure 3-12 for the convention as used POS MV. (Right hand
orthogonal system.)