14
Configuration
Teledyne PDS - Teledyne PDS, T20-P and POS MV Quick Setup
Step
Action
5
Turn off the
firewall in the dialog box and press ‘
Ok
’ to confirm.
6
The firewall is turned off
The computer is ready for use.
3.3.2 Configure T20-P TCP/IP Settings
The T20-
P’s IP address is configured with the SeaBat User Interface
(SUI).
There are two options:
Generate a IP address automatically;
Use static IP address.
The T20-P has the follow default static IP addresses:
LAN1: 10.11.10.1
LAN2:10.11.10.2
The static IP range of the T20-
P’s LAN2 port is between 10.11.10.2 and
10.11.10.9 On this way it is very easy to configure an IP number for the
T20-P processor as you now know the range of the port.
In case of generation an IP address automatically a DHCP server must
available. The processor will acquire an IP address from the DHCP
server.
The following table describes the procedure to change the IP number of
the T20-P.