PS200
PORTABLE GAS MONITOR
OPERATING PARAMETERS & SENSOR TYPES
64171, Rev. 11/December 2019
A-1
A. OPERATING PARAMETERS & SENSOR TYPES
A.1. Typical Operating Parameters
Gas
Range
Resolution
Response Time
LEL
0 to 100%
1%
10 secs. (IEC 60079-26-1)
Oxygen (O
2
)
0 to 25%
0.1%
12 secs. (BSEN 50104)
Carbon Monoxide (CO)
0 to 1000 ppm
1 ppm
<20 secs.
Hydrogen Sulfide (H
2
S)
0 to 9.9 ppm
10 to 100 ppm
0.1 ppm
1 ppm
<20 secs.
Physical Properties
Dimensions (H x W x D):
4.8” x 2.3” x 1.3” (121 mm x 59 mm x 32 mm)
Weight with Pump:
8 oz. (230 g)
Weight with Pump:
7.6 oz (215 g)
Environment
Operating Temperature
Limits:
-4ºF to +122ºF (-20ºC to +50ºC)
Storage Temperature Limits:
-40ºF to +149ºF (-40ºC to +65ºC)
Humidity:
0 to 95% R.H non-condensing
Nominal Flow Rate:
0.132 to 0.185 gals / min (0.5 to 0.7 liters / min) Max. 97 ft. (30 m) sample line.
Typical Flow Fail Rate:
0.026 to 0.053 gals / min (0.1 to 0.2 liters / min)
Warm-up/Stabilization Time
~30 seconds (~90 seconds for monitors with IR flammable sensor options)
Alarms
Visual:
Highly visible, flashing LED
Audible:
Sounder >90 dB
Display
Green/Red LCD backlit display
Power Source
Battery:
Rechargeable Lithium-Ion
Runtime:
Up to 14 hours (8 hours pumped)
Runtime Using Lo Power LEL
Sensor:
Up to 80 hours (20 hours pumped)
Charging Time:
Up to 4 hours
Construction
High-impact, rubberized polycarbonate case. Can withstand physical impact testing to EN 60079 section 1-5
IP Rating
IP67
Datalogging
Timed:
Minimum of 6 months datalogging*
Session:
Minimum of 360 logs
Calibration:
Minimum of 8 logs
Bump:
Minimum of 360 logs
*Based on 1 gas event every 1 hour during a typical 8-hour shift, with a datalogging interval of 1 minute.
Содержание PS200 Series
Страница 10: ...64171 Rev 11 December 2019 x PS200 PORTABLE GAS MONITOR LIST OF TABLES This page is intentionally left blank ...
Страница 20: ...PS200 PORTABLE GAS MONITOR INTRODUCTION 64171 Rev 11 December 2019 2 4 This page is intentionally left blank ...
Страница 34: ...PS200 PORTABLE GAS MONITOR ALARMS 64171 Rev 11 December 2019 4 4 This page is intentionally left blank ...
Страница 54: ...PS200 PORTABLE GAS MONITOR ACCESSORIES 64171 Rev 11 December 2019 10 2 This page is intentionally left blank ...