4. Inspect (INSPT) Mode
4.1. General
Inspect (INSPT) mode records the % Volume Gas readings during an inspection. This data can be
transferred, via Bluetooth, to an app running on a smart device.
4.2. Button Functions
4.3. Operation
To enter INSPT mode, press both buttons until the INSPT screen appears.
Figure 24: INSPT Mode
4.3.1. Range
INSPT mode can display either the % Volume Gas or the PPM CO readings. INSPT mode opens in
the % VOL range. To switch to the PPM CO range, press and hold the L button (RANGE). The PPM
CO range will appear. To switch back to % VOL range, press and hold the L button (RANGE)
again.
Table 4-1: INSPT Mode Key Features
Ranges
Alarm Set-points
Datalogging
Options
Ranges Logged
% Gas
0.1% Gas
Manual
% Gas
ppm CO
35ppm CO
Auto
Table 4-2: Button Function
Action
L Button
Both
R Button
Single Press
Manual Log
—
Light/Max/Live
Press & Hold
Range
OFF (3 seconds)
PUMP Toggle
Alarm Acknowledge