Linea CL Series Camera
Appendix A: GenICam Commands
•
61
I/O Controls Category
The Linea CL I/O controls, as shown by CamExpert, groups features used to configure external
inputs and acquisition actions based on those inputs, plus camera output signals to other devices.
Parameters in gray are read only, either always or due to another parameter being disabled.
Parameters in black are user set in CamExpert or programmable via an imaging application.
Features listed in the description table but tagged as Invisible are usually for Teledyne DALSA or
third party software usage—not typically needed by end user applications.
I/O Control Feature Descriptions
The following table describes these features along with their view attribute and minimum camera
firmware version required. Additionally the Standard & View column will indicate which parameter
is a member of the DALSA Features Naming Convention (indicated by DFNC), versus the GenICam
Standard Features Naming Convention (SFNC not shown).
Display Name
Feature & Values
Description
Standard
& View
Trigger Selector
TriggerSelector
Displays the type of trigger to configure with the
various Trigger features. <RO>
Beginner
LineStart
LineStart Selects a trigger starting the capture of a single
line.
Trigger Mode
TriggerMode
Controls the enable state of the selected trigger.
Beginner
Off
Off The selected trigger is turned off.
On
On The selected trigger is turned active.
Trigger Source
TriggerSource
Diplays the internal signal or physical input line
used as the trigger source. <RO>
The selected trigger must have its TriggerMode
set to ON.
Beginner
CC1
CC1 CC1 used as the external trigger source.