1. Tabs
Available tabs depend on user type;
• An
admin
sees the
Camera
,
Administration
,
Settings
, and
Library
tabs.
• A
user
sees the
Camera
,
Settings
, and
Library
tabs.
• A
viewer
sees the
Camera
tab.
2. Live image
This is where the live image is presented of what the camera is currently targeting.
3. Toolbar
The toolbar options are grouped into the following categories;
•
Measurement tools
•
Data presentation modes
•
Calibration tools
•
View modes
4. Active measurements
Any measurement tools added to the image are displayed and managed from here.
10.4
Camera
tab
The
Camera
tab is the default tab after logging in. Here it is possible to view the live im-
age stream from the camera, make measurements, set alarms, take snapshots, calibrate
the camera, manage image settings, etc.
Note
Available functionality depends on the type of your FLIR camera; Image Stream-
ing camera or Smart Sensor camera.
10.4.1
Working with measurement tools
To measure a temperature, you can use one or more measurement tools, e.g., a spot, a
box, or a delta. The measurement tools are labeled with a number for identification, ac-
cording to the order of their creation. Added measurement tools show up in the
Active
measurements
section, where the they can be managed and where the measured tem-
peratures are displayed.
10.4.1.1
Spot
A spot measurement tool shows the temperature of a specific spot in the image. It is pos-
sible to add up to ten spots.
To add a spot measurement tool, follow this procedure:
1. On the toolbar and in the
Measurement tools
section, click
Spot
.
2. In the image, click to insert the spot. The tool is labeled with a number, and it is also
displayed in the
Active measurements
section.
3. To move the tool, click and hold the tool label in the image, and then move it into
position.
4. To configure
Settings
for the tool, click
next to the tool in the
Active measure-
ments
section. This displays the
Settings
dialog box.
4.1.
To change the label of the tool, change the
Spot name
.
4.2.
To set local parameters for the tool, see section 10.4.3.2
,
page 24.
5. To associate an alarm with the tool, see section 10.4.2
6. To remove the tool, click
Settings
next to the tool in the
Active measurements
section, and then click
Delete measurement
.
#T810579; r. AB/78918/78918; en-US
17
Содержание 89829-0201
Страница 42: ...Pin configurations 11 Figure 11 2 Ethernet cable M12 to RJ45 T810579 r AB 78918 78918 en US 38...
Страница 47: ...A series connection board 12 12 1 Connection examples See next page T810579 r AB 78918 78918 en US 43...
Страница 54: ...Mechanical drawings 14 See next page T810579 r AB 78918 78918 en US 50...
Страница 56: ...EU Declaration of conformity 15 See next page T810579 r AB 78918 78918 en US 52...