5 – Operating Software
DPN 402196 Issue 4.1
© Teledyne TSS
5- 7
NOTE
When a Target Scaling value of greater than 2000uV is used, the RunView display
colour scheme is modified. See section 5.3.2 "View Menu" on page 5-14 for a
detailed explanation of the relevant changes.
5.2.3.2 Threshold
Set an appropriate value for threshold.
High settings will make the 440 System less sensitive to noise but will also decrease its operating
range. The default setting of 15µV has proved to be suitable for the majority of survey operations.
However, Teledyne TSS recommend using 25µV to minimise noise sensitivity and maximise operating
range.
If the recommended threshold value of 25µV does not provide the performance requirements from the
system or it is not clear what the required threshold value should be, always use the default value of
15µV.
5.2.3.3 Seawater Compensation
The 440 System uses a compensation method to distinguish signals arising from seawater and the
target.
To do this, it is necessary for the software to know the conductivity of the seawater surrounding the
coils and ROV during the survey. The conductivity is strongly determined by the water temperature,
and for convenience this has been grouped into bands of 0-10
o
C, 10-25
o
C and >25
o
C.
Select a suitable band.
This assures that salinity is between 30 and 33 psu, in areas where salinity is high (e.g. Mediterranean)
or river outfalls reduce salinity (e.g. Black Sea) then manual compensation may be necessary. Refer to
for further details.
Note that surface water temperature may be considerably higher than the temperature at depth. Below
200m, the water temperature is typically 4
o
C.
NOTE
The seawater rejection algorithm only functions correctly for ROV altitudes below
approximately 4m. Above this height the target signal may ‘jump’ even if no target
is present. This is not a deficiency in the system.
The seawater rejection algorithm has proven reliable, and gives only small errors
(30µV at 3m altitude) if the incorrect temperature band is selected. However, in
shallow or fresh water, performing a manual seawater compensation as explained
in appendix A may be beneficial.
Содержание 440
Страница 12: ...List of Figures x Teledyne TSS DPN 402196 Issue 4 1 ...
Страница 16: ...Revision History xiv Teledyne TSS DPN 402196 Issue 4 1 1 0 Feb 19 2003 First Issue Issue No Date Details ...
Страница 18: ...Glossary xvi Teledyne TSS DPN 402196 Issue 4 1 ...
Страница 24: ...1 Introduction 1 6 Teledyne TSS DPN 402196 Issue 4 1 ...
Страница 32: ...2 System Overview 2 8 Teledyne TSS DPN 402196 Issue 4 1 ...
Страница 66: ...4 Electrical Installation 4 20 Teledyne TSS DPN 402196 Issue 4 1 ...
Страница 88: ...5 Operating Software 5 22 Teledyne TSS DPN 402196 Issue 4 1 Figure 5 10 Altimeter Test ...
Страница 144: ...6 Operating Procedure 6 40 Teledyne TSS DPN 402196 Issue 4 1 ...
Страница 154: ...7 Operational Considerations 7 10 Teledyne TSS DPN 402196 Issue 4 1 ...
Страница 164: ...8 System Specifications 8 10 Teledyne TSS DPN 402196 Issue 4 1 ...
Страница 203: ...10 System Drawings DPN 402196 Issue 4 1 Teledyne TSS 10 17 Figure 10 15 SDC10 Dimensions ...
Страница 204: ...10 System Drawings 10 18 Teledyne TSS DPN 402196 Issue 4 1 Figure 10 16 400604 1 Power Supply Chassis Assembly ...
Страница 205: ...10 System Drawings DPN 402196 Issue 4 1 Teledyne TSS 10 19 Figure 10 17 400667 1 Main Chassis Assembly ...
Страница 206: ...10 System Drawings 10 20 Teledyne TSS DPN 402196 Issue 4 1 Figure 10 18 400667 2 Main Chassis Assembly ...
Страница 209: ...10 System Drawings DPN 402196 Issue 4 1 Teledyne TSS 10 23 Figure 10 21 400654 1 PSU Filter Assembly ...
Страница 210: ...10 System Drawings 10 24 Teledyne TSS DPN 402196 Issue 4 1 Figure 10 22 490232 1 Processor Pod Assembly ...
Страница 211: ...10 System Drawings DPN 402196 Issue 4 1 Teledyne TSS 10 25 Figure 10 23 490228 1 Power Supply Pod Assembly 110v version ...
Страница 212: ...10 System Drawings 10 26 Teledyne TSS DPN 402196 Issue 4 1 Figure 10 24 500045 1 Coil Mounting Frame ...
Страница 213: ...10 System Drawings DPN 402196 Issue 4 1 Teledyne TSS 10 27 Figure 10 25 B930892 1 Coil Assembly ...
Страница 214: ...10 System Drawings 10 28 Teledyne TSS DPN 402196 Issue 4 1 Figure 10 26 601004 1 Coil Cable Assembly ...
Страница 215: ...10 System Drawings DPN 402196 Issue 4 1 Teledyne TSS 10 29 Figure 10 27 B930473 1 PSU to ROV PWR COMMS Cable 3 0m ...
Страница 230: ...A Operating Theory A 12 Teledyne TSS DPN 402196 Issue 4 1 ...
Страница 242: ...B Options B 12 Teledyne TSS DPN 402196 Issue 4 1 ...
Страница 244: ...C Altimeter C 2 Teledyne TSS DPN 402196 Issue 4 1 ...
Страница 246: ...D Reference D 2 Teledyne TSS DPN 402196 Issue 4 1 ...
Страница 248: ...D Reference D 4 Teledyne TSS DPN 402196 Issue 4 1 ...
Страница 250: ...D Reference D 6 Teledyne TSS DPN 402196 Issue 4 1 ...
Страница 252: ...D Reference D 8 Teledyne TSS DPN 402196 Issue 4 1 ...
Страница 254: ...D Reference D 10 Teledyne TSS DPN 402196 Issue 4 1 ...