4250 Flow Meter
Section 2 Programming
2-24
If you select SERIAL OUTPUT from the OPTIONAL OUTPUTS
menu, the following display will appear:
Selection of OFF from this menu will disable this feature, and
there will be no further references to it. The Serial Output data
appears on the Interrogator connector of the flow meter. You
should not use a standard interrogator cable for this application,
as the sense line in the standard cable is shorted to ground.
Selection of ON from this menu will enable the feature and cause
the following display to appear:
After you select the appropriate baud rate, the program will
advance to the following menu:
This menu lets you select how often the flow meter transmits the
ASCII text string.
Following is an example of a string showing all options. In actual
practice, there are no carriage returns in the text string.
DE, Theresa Street, ID,0721577657,
MO,4250,TI,35317.343715,BV,12.3,LE,0.1000,VE,0.1225,FL,
0.001555,VO,2.199325,FV,2.199325,RV,0.000000,SV,2.1955
39,SS,1,B0,35317.307384,B0,35317.269907,B0,35317.2325
93,CS,10819
If you select any of these outputs, the flow meter will request
that you turn them on or off. If you are running on battery and do
not need these options, select OFF. Otherwise, select ON. After
the OPTIONAL OUTPUTS menus have been set, press
Enter
.
The display will return to the SETUP menu.
The alarm box, also called the
High-Low Alarm Box
,
allows
you to operate control relays to signal alarms when flow rate
rises above or falls below a certain set value. You can set both the
high and low alarm values from 1 to 99% of the controlling con-
dition. (See Section 5 for more information about the alarm box.)
If you select any of these outputs, the flow meter will request
that you turn them on or off. If you are running on battery and do
not intend to use either of these options, select OFF. Otherwise,
select ON. After the OPTIONAL OUTPUTS menus have been
set, press
Enter
. The display will return to the SETUP menu.
This time, select REPORT SETUP with the
arrow
key. Press
Enter
.
PERIODIC SERIAL OUTPUT
• ON • • OFF
SELECT BAUD RATE (N81)
• 9600 • • 4800 • • 2400 • • 1200 •
SERIAL OUTPUT INTERVAL
• 15 SEC • • 1 MIN • • 5 MIN • • 15 MIN •
REPORT SETUP
• REPORT A • • REPORT B •
Содержание 4250
Страница 2: ......
Страница 4: ......
Страница 12: ...4250 Flow Meter Table of Contents x ...
Страница 28: ...4250 Flow Meter Section 1 Introduction 1 16 ...
Страница 90: ...4250 Flow Meter Section 2 Programming 2 62 ...
Страница 140: ...4250 Flow Meter Section 4 Options and Accessories 4 30 ...
Страница 160: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 2 ...
Страница 161: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 3 ...
Страница 166: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 8 ...
Страница 184: ...4250 Flow Meter Appendix C General Safety Procedures C 10 ...
Страница 191: ...4250 Flow Meter Appendix D Material Safety Data Sheets D 7 ...
Страница 192: ...4250 Flow Meter Appendix D Material Safety Data Sheets D 8 ...
Страница 196: ......
Страница 198: ......
Страница 200: ......
Страница 202: ...Warranty ...
Страница 204: ......