4250 Flow Meter
Section 3 Installation
3-11
3.5 Extension Cables
The 10-foot range and low profile AV sensors are provided with
25 feet of cable. The 30-foot range AV sensor is provided with 50
feet of cable. If these lengths are insufficient, it is possible to
connect an extension cable between the flow meter and the AV
sensor. Teledyne Isco provides a 25-foot extension cable for either
sensor.
CAUTION
The AV sensor extension cables and the AV sensor cable
can-
not
be cut for any reason, or they will be ruined. The connec-
tors are factory-sealed and neither the cable nor the vent tube
inside can be satisfactorily spliced in the field.
Teledyne Isco does not
recommend connecting more than two
extension cables together to exceed the 75-foot limit (100 ft. for
the 30 ft. sensor). Increasing the length of the vent tube
beyond 75 feet slows the response of the pressure transducer,
and this may cause measurement errors. For greater distances
use the Quick-Disconnect Box and a custom-built cable.
Figure 3-6 Assembling a Compression Bushing
The AV sensor uses a differential pressure transducer and two
ultrasonic transducers. The cable connecting the AV sensor to the
flow meter contains a small tube that references the pressure
transducer to atmospheric pressure. This allows a true differ-
ential pressure measurement unaffected by changes in baro-
metric pressure. This tube is vented through the connector into
the cabinet of the 4250. From there, it is vented to the atmo-
sphere through a desiccant cartridge mounted on the side of
either the flow meter or the Quick-Disconnect Box.
Содержание 4250
Страница 2: ......
Страница 4: ......
Страница 12: ...4250 Flow Meter Table of Contents x ...
Страница 28: ...4250 Flow Meter Section 1 Introduction 1 16 ...
Страница 90: ...4250 Flow Meter Section 2 Programming 2 62 ...
Страница 140: ...4250 Flow Meter Section 4 Options and Accessories 4 30 ...
Страница 160: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 2 ...
Страница 161: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 3 ...
Страница 166: ...4250 Flow Meter Appendix A Replacement Parts and Accessories A 8 ...
Страница 184: ...4250 Flow Meter Appendix C General Safety Procedures C 10 ...
Страница 191: ...4250 Flow Meter Appendix D Material Safety Data Sheets D 7 ...
Страница 192: ...4250 Flow Meter Appendix D Material Safety Data Sheets D 8 ...
Страница 196: ......
Страница 198: ......
Страница 200: ......
Страница 202: ...Warranty ...
Страница 204: ......