background image

WorkHorse Rio Grande ADCP User's Guide 

page 2 

RD Instruments 

WorkHorse Rio Grande ADCP Applications 

The Workhorse Rio Grande ADCP provides customers with reliable and 
repeatable river discharge measurements, and displays the results through 
its exceptional, user-friendly 

WinRiver

 software.  For detailed information 

on how to use 

WinRiver

, see the 

WinRiver

 User’s Guide

.   

The WorkHorse Rio Grande ADCP can also be used in other moving vessel 
real time applications that take advantage of the Rio Grande’s bottom track-
ing abilities.  

WinRiver

 is the most often used software package for Rio 

Grande ADCP setup, real-time data collection, and data review.  RDI also 
offers the 

VmDas

 program for ADCP setup, real-time data collection, and 

data review.  For detailed information on how to use 

VmDas

, see the 

VmDas 

User’s Guide

.   

Table  1: 

WorkHorse Rio Grande Application Guide 

Estuaries/River 

Costal and Continental Shelf 

Rio Grande using WinRiver 

Rio Grande using VmDas 

• 

River, stream and channel discharge 

• 

Plume tracking 

• 

Suspended sediment load estimation 

• 

Environmental surveys 

• 

Plume tracking 

• 

Planning new ports 

• 

Bridge scouring 

• 

Current mapping 

• 

Simultaneous bathymetry discharge, flow structure 

• 

Costal engineering 

 

• 

Cable and pipe laying 

 

• 

Circulation/model studies 

 

3 System 

Overview 

The WorkHorse Rio Grande is designed to measure real-time current pro-
files from temporary or permanent mounting in a vessel.  The Rio Grande 
ADCP system consists of an ADCP with Bottom Track mode, High Resolu-
tion Water Profiling modes, cables, and software.  The input power re-
quirements for the Rio Grande are +12 VDC.  The Rio Grande system re-
quires the addition of a Windows® compatible computer to collect data. 

 

NOTE.  

Do not attempt to attach a Workhorse Monitor/Sentinel I/O cable or 

power supply to the Workhorse Rio Grande ADCP.  The Workhorse 
Monitor and Sentinel ADCPs are 24 VDC systems.  

The Workhorse Rio 

Grande uses 12 VDC only. 

 

 

NOTE.  

The Rio Grande End-Cap is red to differentiate it from the Monitor 

and Sentinel ADCPs.  Do not swap end-caps between a Rio Grande and a 
Monitor/Sentinel.  The pin-outs are different on both the I/O cable 
connector and the internal I/O cable. 

 

Содержание WorkHorse Rio Grande ADCP

Страница 1: ...WorkHorse Rio Grande ADCP User s Guide P N 957 6167 00 January 2001 RD Instruments Acoustic Doppler Solutions...

Страница 2: ......

Страница 3: ...llation 11 6 3 Utility Software 12 7 Power 13 7 1 Bench Top Battery Power Requirements 13 7 2 Operation Modes 13 8 Testing Your WorkHorse 14 9 Compass Calibration 15 9 1 Preparing for Calibration 15 9...

Страница 4: ...orkHorse Rio Grande Connections 10 Figure 6 Compass Alignment 17 Figure 7 Visual Inspection before Deployment 19 Figure 8 Prepare the ADCP 20 Figure 9 Real Time Deployment 21 List of Tables Table 1 Wo...

Страница 5: ...Technical Manual guides Where needed there are references to detailed information and fig ures contained in the WorkHorse Technical Manual WorkHorse Rio Grande deployments are most often Real Time Rea...

Страница 6: ...nd channel discharge Plume tracking Suspended sediment load estimation Environmental surveys Plume tracking Planning new ports Bridge scouring Current mapping Simultaneous bathymetry discharge flow st...

Страница 7: ...ramics Never set the transducer on a hard surface The urethane face may be damaged Housing The standard WorkHorse housing allows deployment depths to 200 meters Thermistor The Thermistor measures the...

Страница 8: ...Horse Rio Grande ADCP User s Guide page 4 RD Instruments URETHANE FACE BEAM 3 MARK THERMISTOR PRESSURE SENSOR OPTIONAL TRANSDUCER HEAD HOUSING END CAP I O CABLE CONNECTOR Figure 1 Rio Grande ADCP Over...

Страница 9: ...on the end cap connector as the I O cable is being disconnected Stressing the end cap connector may cause the ADCP to flood Read the Maintenance guide for details on disconnecting the I O cable Figure...

Страница 10: ...7 are available in 16 20 40 85 and 220 MB cards The internal recorder holds two cards for a maximum of 440 MB of recording space The PC Card recorder is located on the Digital Signal Processor DSP bo...

Страница 11: ...page 7 Figure 4 Memory Card Overview 3 4 Spare Parts The following parts are included in the spare parts kit Table 2 Spare Parts Description Part number O ring face 2 260 Desiccant sealed bag DES3 Lu...

Страница 12: ...ns ducer faces on the Workhorse if it will be exposed to sun light Do not expose the I O connector to prolonged sunlight The plastic may become brittle Cover the connector on the Workhorse if it will...

Страница 13: ...you connect the cable with power applied you may see a small spark The connector pins may become pitted and worn The WorkHorse I O cable is wet mate able not under water mate able 4 3 Deployment Guid...

Страница 14: ...standard communications settings for a WorkHorse Rio Grande is RS 232 9600 baud no parity 8 data bits and 1 stop bit If the serial protocol is set for RS232 and your computer expects RS422 you will n...

Страница 15: ...to use WinADCP see the WinADCP User s Guide Documentation CD The Documentation CD has an Adobe Acrobat pdf elec tronic version of the WorkHorse Technical Manual Use the Documentation CD to search for...

Страница 16: ...I comma delimited format data described by a decoder DEC file into the raw BroadBand ADCP data file infilename result ing in an output ADCP data file called outfilename See BCONV DOC for decoder file...

Страница 17: ...se is asleep it consumes less than one mw A standard battery pack supplies sleep power for years At every opportunity the WorkHorse will sleep to conserve power while de ployed 7 2 Operation Modes The...

Страница 18: ...the tests DumbTerm runs gives you guidelines for running the tests and tells you what the results mean Table 5 WorkHorse ADCP Tests Test Guidelines Results PS0 Displays system parameters Verify the i...

Страница 19: ...orse on a piece of strong cardboard on top of a smooth wooden non magnetic table If a wooden table is not available place the WorkHorse on the floor as far away from metal objects as possible Use the...

Страница 20: ...vious cali bration While you are turning the WorkHorse for the two calibration rota tions the WorkHorse checks the quality of the previous calibration and dis plays the results It compares these resul...

Страница 21: ...the calibration procedure is not successful return your WorkHorse to the original factory calibration by using the AR command Try using the AR command if you have trouble calibrating your compass In s...

Страница 22: ...fouling The sensor port is surrounded by the antifouling paint but bio fouling may build up on the screw and eventually clog the sensor port However most organ isms do not seem to find the small amoun...

Страница 23: ...dition All mounting hardware installed Transducer faces clean and free from defects Verify compass alignment using DumbTerm if necessary re calibrate Are biofouling precautions needed Zero pressure se...

Страница 24: ...t specified WorkHorse deployment depths and temperatures Remember that desiccant rapidly absorbs moisture from normal room air Replace the desic cant whenever the WorkHorse housing or end cap is re mo...

Страница 25: ...s The Workhorse corrects data for tilts as large as 15 but tilts reduce the effective range and increase the depth of surface contamination Anti fouling paint You are free to use any anti fouling pain...

Страница 26: ...l to the average sound speed if the average sound speed is 1 less than the sound speed at the transducer the distance to the depth cell is 1 less than the displayed distance 12 2 When was the Data The...

Страница 27: ...angles the WorkHorse maps depth cells to other cells at the same depth If you want to make measurements near the surface from a bottom mounted WorkHorse you should minimize the tilt Depth cells are m...

Страница 28: ...group in any of the following ways RD Instruments RD Instruments Europe 9855 Businesspark Ave 5 Avenue Hector Pintus San Diego California 92131 06610 La Gaude France 858 693 1178 33 0 492 110 930 FAX...

Отзывы: