WaveSurfer 3000z
Oscilloscopes
Getting Started Guide
Страница 1: ...WaveSurfer 3000z Oscilloscopes Getting Started Guide...
Страница 2: ...distribute Teledyne LeCroy documentation for internal educational purposes Teledyne LeCroy is a trademark of Teledyne LeCroy Inc Other product or brand names are trademarks or requested trademarks of...
Страница 3: ...uals can be downloaded from the Oscilloscope Manuals page on our website at teledynelecroy com support techlib Introduction Introducing WaveSurfer 3000z Oscillosocopes 2 Key Specifications 2 Materials...
Страница 4: ...tes the Most Advanced User Interface MAUI through a 10 1 capacitive touch screen It promotes true versatility with 20 Mpts of memory multi instrument capabilities a powerful deep toolbox and 100 MHz 1...
Страница 5: ...nd use the built in carrying handle to move the instrument Use indoors only Keep product surfaces clean and dry Do not block the cooling vents Leave a minimum six inch 15 cm gap between the instrument...
Страница 6: ...Touch Screen Display B Front Panel C Ground and Calibration Terminals D USB 2 0 Ports E Mixed Signal Interface F Channel Inputs G Rotating Tilting Feet H Power On Off Button Front of Oscilloscope OVER...
Страница 7: ...ed for your country to the AC power inlet on the back of the instrument then plug it into a grounded AC power outlet see Power and Ground Connections in Safety The Power button controls the operationa...
Страница 8: ...aveSource Output C Kensington Lock D Micro SD Card removable drive E EXT Trigger Input F AUX Output G VGA Video Output to external monitors H Ethernet Port I USBTMC Port for remote control J USB 2 0 P...
Страница 9: ...ey Trigger Out To send a trigger pulse to another device connect a BNC cable from the AUX output on the back of the instrument to the other device LAN WaveSurfer 3000z is preset to accept DHCP network...
Страница 10: ...t features two digital banks with separate threshold controls making it possible to simultaneously view data from different logic families Each flying lead has a signal and a ground connection A varie...
Страница 11: ...o your Hardcopy settings e g print email or save to file or creates a Notebook Entry in LabNotebook if configured for it The Touch Screen button enables or disables touch screen functionality The Adju...
Страница 12: ...play information also work as buttons to access other functions If you have a mouse installed you can click anywhere you can touch to activate a control in fact you can alternate between clicking and...
Страница 13: ...below the grid and summarize current settings for each open trace Touch the descriptor box to open the corresponding set up dialog Timebase and Trigger descriptor boxes appear at the right of the dis...
Страница 14: ...rtical precision is always maintained 256 Vertical Levels 256 Vertical Levels By default the oscilloscope has the Auto grid mode enabled Auto adds a new grid for each new type of trace analog channel...
Страница 15: ...currently represented by the extreme Vertical and Horizontal margins of the grid When more data is available than can actually be displayed Trace Intensity helps to visualize significant events by ap...
Страница 16: ...the grid area when a trace is turned on Descriptor boxes summarize and activate the traces they represent Inactive Controls will not work for this trace Active Controls will work for this trace Activ...
Страница 17: ...you have a keyboard installed you can type entries in an active data entry field Or you can touch again then type the entry by touching keys on the virtual keypad or keyboard To use the virtual keypa...
Страница 18: ...add positive or negative Offset The front panel Volts knob also controls the Vertical Scale of zoom math and memory traces Channel Descriptor Box Volts div Gain Offset Pre Processing Summary List cha...
Страница 19: ...scriptor once to reactivate the trace twice to reopen the Cn dialog Refine Volts div or Offset Enter Attenuation for non Teledyne LeCroy probes Optionally change Vertical Unit of grid from Volts to Am...
Страница 20: ...ive Digital line and bus traces Turn Offset to raise lower group Vertical Position the top of lowest bit relative to center Turn Volts to raise lower Group Height the total Vertical divisions occupied...
Страница 21: ...c Family or enter a custom Threshold Separate controls allow you to set different values for each lead bank Choose a Display Mode of individual digital lines bus trace or both Optionally choose a new...
Страница 22: ...you add positive or negative Delay time The front panel Time knob also controls the Horizontal Scale of zoom math and memory traces allowing you to zoom in to see more detail or zoom out to see the b...
Страница 23: ...lt is the maximum available From the Touch Screen Touch the Timebase descriptor to open Timebase setup dialog Optionally enter Delay negative time before or positive time after trigger event to show S...
Страница 24: ...id when trigger point is no longer visible Triggers Triggers tell the oscilloscope when to perform an acquisition The acquisition starts as soon as the trigger is armed and all trigger conditions are...
Страница 25: ...escriptor to open Trigger setup dialog Choose trigger Type Choose trigger Source channel Set trigger Level or Find Level based on the input signal Set other conditions such as Slope and Coupling vary...
Страница 26: ...visible BASICS From the Front Panel Create Zoom of all open traces The Zoom descriptor box shows the Zoom Source and Horizontal Scale which differs from the Timebase Adjust Horizontal Scale to change...
Страница 27: ...p dialog touch Zoom Action Toolbar button to create a new zoom of just that source trace Zoom descriptor opens Zoom dialog to make other adjustments Draw a Zoom box over a portion of the source trace...
Страница 28: ...perator s Manual All show the absolute value where the cursor intersects the waveform and the delta of the two lines From the Front Panel From the Touch Screen Cursors Cursor Setup opens the Cursor di...
Страница 29: ...more traces and view the active readout in a table below the grid Statistics can be added to the readout along with histicons a miniature histogram of the statistical distribution You can also gate m...
Страница 30: ...trace Fn tab to set up change function Math Math creates a new trace that displays the result of applying a mathematical function e g Sum Product FFT to one or more source traces Operations can be ch...
Страница 31: ...pe is rebooted To store memories indefinitely save them to an external file by choosing File Save Waveform The file can then be recalled into one of the two internal memories for viewing by choosing F...
Страница 32: ...eSurfer 3000z To use it just connect a BNC cable from the WaveSource output on the back of the oscilloscope to the input device and set up the waveform on the WaveSource dialog To access WaveSource Pr...
Страница 33: ...ts and other user data files can be emailed directly from the instrument or saved to accessible network devices The oscilloscope can be added to a LAN via TCP IP or directly connected to a PC via USBT...
Страница 34: ...mperature range the WaveSurfer 3000z will meet all specifications once warmed up Warm up the WaveSurfer 3000z for at least 20 minutes prior to each use so it can reach a stable operating temperature S...
Страница 35: ...e USB Disk folder then select Upgrade 9 When installation is complete reboot the instrument CAUTION The installation may take several minutes depending on the length of time since your last update Do...
Страница 36: ...in transit 5 Mark the outside of the box with the shipping address Add ATTN RMA code assigned by Teledyne LeCroy FRAGILE 6 If returning a product to a different country Mark the shipment Return of US...
Страница 37: ...reases the task duration or difficulty of servicing the instrument Spare and replacement parts and repairs all have a 90 day warranty The instrument s firmware has been thoroughly tested and is presum...
Страница 38: ...etic Field 3 Vrms 0 15 MHz 80 MHz EN 61000 4 11 2004 Mains Dips and Interruptions 0 1 cycle 70 25 cycles 0 250 cycles 4 5 1 To ensure compliance with all applicable EMC standards use high quality shie...
Страница 39: ...ecroy com patents Safety Compliance EC DECLARATION OF CONFORMITY LOW VOLTAGE The oscilloscope meets intent of EC Directive 2014 35 EU for Product Safety Compliance was demonstrated to the following sp...
Страница 40: ...2018 Teledyne LeCroy Inc All rights reserved 929204 00 Rev A April 2018...