Teledyne Lecroy MDA800A Скачать руководство пользователя страница 1

Motor Drive Analyzer 

Getting Started Guide

Содержание MDA800A

Страница 1: ...Motor Drive Analyzer Getting Started Guide...

Страница 2: ...bute Teledyne LeCroy documentation for internal educational purposes Teledyne LeCroy is a trademark of Teledyne LeCroy Inc Other product or brand names are trademarks or requested trademarks of their...

Страница 3: ...troducing Motor Drive Analyzer 2 Safety 2 Overview Front of Motor Drive Analyzer 4 Powering On Off 5 Back of Motor Drive Analyzer 6 Connecting to External Devices Systems 7 Side of Motor Drive Analyze...

Страница 4: ...mes the display area with the unique Q Scape multi tab display architecture with support for UHD 3840 x 2160 pixel external displays HD4096 HD4096 high definition technology consists of 12 bit ADCs hi...

Страница 5: ...arest object Keep the underside clear of papers and other objects Exercise care when lifting and carrying Unplug and use the built in carrying handle to move the instrument Do not remove the covers or...

Страница 6: ...nel C Shortcut Buttons D Built in Stylus Holder E Power On Standby Button F Input Channels 1 4 G EXT Input H Mixed Signal Interface I Ground and Cal Out Terminals J USB Ports K Tilting Feet Front of M...

Страница 7: ...ill remain unused for a long period of time CAUTION Do not change the Windows Power setting to System Standby or System Hibernate Doing so may cause failure OVERVIEW The touch screen display is the pr...

Страница 8: ...Built in Carrying Handle B Ref In Out C Aux Out D USBTMC Port E Ethernet Ports 2 F USB 3 0 Ports 4 G DisplayPort H Audio In Out I AC Power Inlet J Kensington Lock A B C D E Back of Motor Drive Analyze...

Страница 9: ...Connections from the Remote dialog and use the Windows networking dialogs to configure the device address Go to File File Sharing to configure email Remote Control You can control the instrument over...

Страница 10: ...to loosen the knobs 2 Grab the drive by the attached tab and pull out To replace the drive 1 Insert the drive with the label facing away from you Do not force the drive into place Strong resistance ma...

Страница 11: ...d measurement counters F The front panel Adjust knob changes the value in the highlighted data entry field when turned Pushing the Adjust knob toggles between coarse stepped or fine adjustments when t...

Страница 12: ...Setup Dialogs Touch Screen Display The entire display is active Use your finger or a stylus to touch drag and drop swipe pinch and flick Many controls that display information also work as buttons to...

Страница 13: ...s next to the trace descriptor boxes Use it to turn on new traces or the Measure table See MAUI with OneTouch on p 15 The HD Descriptor box shows the ADC resolution at which the instrument is operatin...

Страница 14: ...isplay Mode determines whether the touch screen has a single display or tabs each representing a separate display The Grid Mode allows selection of a particular grid style in each display By default t...

Страница 15: ...cape Display Mode is extended only Tab 1 is moved to the second display Line and Intensity The trace style can be set to a series of separate sample Points or a continuous vector Line Grid Intensity m...

Страница 16: ...races Trace Descriptor Boxes Channel C1 C8 Zoom Z1 Z12 Math F1 F12 Memory M1 M12 and Digital Digital1 Digital4 descriptor boxes appear along the bottom of the grid when a trace is turned on Descriptor...

Страница 17: ...d with a white box When you re moving over invalid targets you ll see the Null symbol under your finger tip or cursor Turn On To turn on a new channel math memory or zoom trace drag any descriptor box...

Страница 18: ...e onto the target descriptor box You can also drop it on the Source field of the target setup dialog To change the source of a measurement drag and drop the descriptor box of the desired source onto t...

Страница 19: ...ange the trigger source channel drag and drop the desired channel Cn descriptor box onto the Trigger descriptor box The trigger will revert to the last trigger set on that channel To place horizontal...

Страница 20: ...escriptor box onto the target memory Mn descriptor box Pan To pan a trace activate it to bring it to the forefront then drag the waveform trace right left or up down If it is the source of any other t...

Страница 21: ...he trace you want to zoom Touch the Zn descriptor box to open the zoom factor controls and adjust the zoom exactly To zoom in on any trace unpinch two fingers over the trace horizontally To zoom out o...

Страница 22: ...Apply filters and or hysteresis to improve its quality Touch tab or icon to open the setup dialog for each motor drive power section Choose the Wiring Configuration for each power section Diagram show...

Страница 23: ...to choose the voltage current power real apparent and reactive phase angle power factor efficiency and mechanical measurements shown on the table The table is displayed with the acquisition waveforms...

Страница 24: ...ccess the Waveforms Stats dialog for you to select and modify them Touch MP cell in the Numerics table to create a per cycle Waveform and show statistics MPs with Waveforms are highlighted on the Nume...

Страница 25: ...e measurements shown on the Numerics and Statistics tables are gated to the number of measurement cycles shown in the zooms Press Zoom Gate again to turn off the zooms and return to the original displ...

Страница 26: ...ode no tabs Timebase and Trigger descriptor boxes remain outside tabs when in Q Scape display modes Touch the Q Scape soft button on the menu bar to change the display mode Touch and hold right click...

Страница 27: ...d LabNotebooks reports and other user data files can be emailed directly from the instrument or saved to accessible network devices Files can also be transferred to a USB drive through any of the host...

Страница 28: ...fset The front panel Volts knob also controls the Vertical Scale of zoom math and memory traces Channel Descriptor Box From the Front Panel Turn on activate channel trace and open set up dialog Raise...

Страница 29: ...d New box and choose Channel Touch new Cn descriptor to open the Cn setup dialog Enter Attenuation for passive and other vendors probes Enter Volts div and Offset Rescale channel trace or change Verti...

Страница 30: ...ory Digital Lines in Group Digital Sample Rate Digital Displays Line trace shows high low and transition points for each line Bus trace collapses lines into hex values Turn on activate digital traces...

Страница 31: ...pen Digitaln setup dialog From the Touch Screen Choose Display Mode of individual lines bus trace or both Line Activity indicators show the state of each line high low or transitioning Optionally choo...

Страница 32: ...negative Delay time The front panel Time knob also controls the Horizontal Scale of zoom math and memory traces allowing you to zoom in to see more detail or zoom out to see the bigger picture BASICS...

Страница 33: ...oints of memory to use in acquisition From the Touch Screen Touch the Timebase descriptor to open Timebase setup dialog Optionally enter Delay negative time before trigger or positive time after trigg...

Страница 34: ...e met unless postponed by a Holdoff count of time or number of trigger events Trigger types and modes are described at more length in the HDO8000A MDA800A Oscilloscopes Operator s Manual From the Fron...

Страница 35: ...h Trigger descriptor to open Trigger setup dialog Choose trigger Type Choose trigger Source channel Set trigger Level or Find Level based on the input signal Icon summarizes the trigger selections Set...

Страница 36: ...ore visible BASICS From the Front Panel Zoom traces Zn display a magnified portion of another trace Any trace can be zoomed although Zoom is most useful for channel traces as it allows you to see the...

Страница 37: ...Zoom box over a portion of the source trace Repeat on another section to reposition the Zoom trace On the source trace setup dialog touch Action Toolbar Zoom button to create a new zoom of just that s...

Страница 38: ...of the two lines From the Front Panel From the Touch Screen Cursors Cursor Setup opens the Cursor dialog Touch and drag cursor line to reposition cursor Vertical Cursor readout on descriptor boxes Ho...

Страница 39: ...d or track of the measurement over time Measurements and Statistics Measure Measure Setup opens the Measure dialog Touch Measure column to re open Measure dialog if closed Pn dialogs to configure user...

Страница 40: ...s a new trace that displays the result of applying a mathematical function e g Sum Product FFT to one or more source traces Operations can be chained by using one math function as a source for the oth...

Страница 41: ...1 M12 Choose Math Memory Setup On the Mn tab select the trace you want stored in Copy From Waveform then touch Copy Now Optionally add Notes or Labels to the stored memory Then drag the descriptor box...

Страница 42: ...ined patterns and events in the data stream BASICS Select Source trace and Protocol View decoding on the colored overlays When there is more data than fits in a table cell touch the white triangle to...

Страница 43: ...enable a quick search for events of interest The results are time stamped tabu lated and can be selected for individual viewing Color overlays mark events on the source trace BASICS Choose scan Mode e...

Страница 44: ...nd the instrument automatically generates output in units relevant to the frequency domain A spectrogram generator displays 2D or 3D renderings of historical data BASICS Tabular readout of marker meas...

Страница 45: ...te time since beginning of history or the time relative to where you are in the history Not only can individual acquisitions be restored to the grid you can replay history at varying speeds to capture...

Страница 46: ...e for a full list of options Calibration The MDA800A is calibrated at the factory prior to being shipped This calibration is run at 23 C 2 C and is valid for temperatures 5 C of the original calibrati...

Страница 47: ...st update Do not power down the oscilloscope at any point during the installation process Switching Windows Users Windows 10 oscilloscopes only Windows 10 oscilloscopes are by default set to operate f...

Страница 48: ...transit 5 Mark the outside of the box with the shipping address Add ATTN RMA code assigned by Teledyne LeCroy FRAGILE 6 If returning a product to a different country Mark the shipment Return of US man...

Страница 49: ...of servicing the instrument Spare and replacement parts and repairs all have a 90 day warranty The instrument s firmware has been thoroughly tested and is presumed to be functional Nevertheless it is...

Страница 50: ...etic Field 3 Vrms 0 15 MHz 80 MHz EN 61000 4 11 2004 Mains Dips and Interruptions 0 1 cycle 70 25 cycles 0 250 cycles 4 5 1 To ensure compliance with all applicable EMC standards use high quality shie...

Страница 51: ...tents Safety Compliance EC DECLARATION OF CONFORMITY LOW VOLTAGE The instrument meets intent of EC Directive 2014 35 EU for Product Safety Compliance was demonstrated to the following specifications a...

Страница 52: ...2019 Teledyne LeCroy Inc All rights reserved 929958 00 Rev A January 2019...

Отзывы: