Figure 4.75 -
Zoomed Throughput Graph
-
Freeze Y
keeps the y-axis constant
Interval Menu
The
Interval
drop-down menu is used to set the duration of each
data point in the Zoomed Throughput graph. The default setting is
Auto
that sets the data point interval automatically depending on the
zoom level. The other menu selections provide the ability to select a
fixed data point interval. Selecting from a larger to a smaller interval
will display more data points. Should the number of data points
exceed 30,000, no data is displayed and a warning will appear in the
graph area.
4.3.4.19 Zoom Cursor
Selecting the
Zoom Cursor
button changes the cursor to the zoom cursor
. The zoom cursor is
controlled by the mouse wheel and zooms the viewport and thus the
and the
. The zoom cursor appears everywhere except the
Throughput Graph
, which is not
zoomable, in which case the scroll cursor is shown. When the zoom cursor is in the
Timelines
or
Zoomed Throughput Graph
zooming occurs around the point in time where the zoom cursor is
positioned. When the zoom cursor is outside the
Timelines
and the
Zoomed Throughput Graph
the
left edge of those displays is the zoom point.
4.3.4.20 Comparison with the
Bluetooth
Timeline's
Throughput Graph
The
Throughput Graph
s for Classic
Bluetooth
in the
Coexistence View
and the
Bluetooth
Timeline
can look quite different even though they are plotting the same data. The reason is that the
Coexistence
View
uses timestamps while the
Bluetooth
Timeline
uses
Bluetooth
clocks, and they do not always match
up exactly. This mismatch can result in the data for a particular packet being included in different intervals
in the two
Throughput Graph
s, and can have a significant impact on the shapes of the two respective
graphs. This can also result in the total duration of the two
Throughput Graph
s being different.
Another factor that can affect total duration is that the
Bluetooth
Timeline
's
Throughput Graph
stops at
the last Classic
Bluetooth
packet while the
Coexistence View
’s
Throughput Graph
stops at the last
packet regardless of technology.
TELEDYNE LECROY
Chapter 4 Capturing and Analyzing Data
159
Frontline BPA 600 Hardware & Software User Manual
Содержание Frontline BPA 600
Страница 1: ...Hardware and Software User Manual Revision Date 3 14 2017...
Страница 296: ...TELEDYNE LECROY Chapter 7 General Information 288 Frontline BPA 600 Hardware Software User Manual...
Страница 297: ...Appendicies Appendix A Application Notes 290 Frontline BPA 600 Hardware Software User Manual 289...
Страница 304: ...TELEDYNE LECROY Appendicies 296 Frontline BPA 600 Hardware Software User Manual...
Страница 310: ...TELEDYNE LECROY Appendicies 302 Frontline BPA 600 Hardware Software User Manual...