3.

 

Handling and use 

 

 

First use 

 

Make yourself familiar with all operation elements of your applicator before you attempt 
to test the applicator and to go into practice.  
 
TeleDart Guns have varying settings to allow you to adopt the applicator to your 
individual requirements.  
 
Before shipment, we test all TeleDart applicators at a distance of 15 m (16.41 yds)  
using a 

TeleDart Dart Syringe (TD03-11/ TD05-13/TD03-16)

 
For your training we recommed to use the supplied traing darts. For training purposes 
it is not necessary to pressurize the dart syringe.  If you have to work with other dart 
volumes please proceed in the same way. Note all pressure values in the pressure 
table which is part of your manual. 

 

Assembling 

 

Slide-in the barrel as far as it goes. Take care that the sight is on your right hand side. 
As soon as the barrel has reached its position, turn the barrel a quarter (90°) to the left 
until the guiding pin situated at the barrel retainer ring locks. 

 

 

Individual Adjustments  (gun) 

 

Adopt the cheek piece and the shoulder support at a position at which you can shoot 
comfortably.  

 

  Inserting of the CO²-cartridge 

 

Unscrew the cartridge holder and insert a CO²-cartridge. Tighten up the cartridge 
holder until the cartridges is tapped. 

       
      Only replace open cartridges if they are completely empty. Further all safety advices  
      marked on the packing of the CO²-cartridges are valid. TeleDart does not take any    
      liability for damages and injuries caused by improper handling of CO²-cartridges. 
 

  Safety 

 

Check if the safety device of the trigger is on safe. The turning knob must be turned to 
the upper position (Pos. “S”). 

 

  Pressurizing 

 

       Airpump: 

The pressure regulation knob must be in “0”- Position. Latch the hose of the airpump  
with the hose- connector. To unlatch the airpump the locking sleeve of the hose 
connector has to be pushed back until the hose unlatches. 

 

CO2: 
The applicator is pressured if you turn the pressure regulation knob maxium one 
quarter (90°) in direction of the „+“-position. Observe the manometer and release the 

Содержание RD406

Страница 1: ...study the following operator s manual carefully and follow all our directions and instructions Then you will be sure to do your remote injections safely and without problems We wish you always a very successful working The Team of TeleDart Pressure table for the TeleDart applicator RD_________ Dear customer Thank you for having chosen a TeleDart applicator This applicator has been tested in a clos...

Страница 2: ...Barrels Syringe volumes interchangeable barrel system with quick connection coupling calibre 11 mm 1 5 ccs ml calibre 13 mm 5 20 ccs ml calibre 16 mm 1 20 ccs ml Short barrel available Maximum range 130 m Effective range with standard barrel calibre 11 mm 60 70 m depending on dart sizes Standard sight back sight front sight Pressure build up CO2 cartridge or airpump Pressure control continuous 0 1...

Страница 3: ...nge volumes interchangeable barrel system with quick connection coupling calibre 11 mm 1 5 ccs ml calibre 13 mm 5 20 ccs ml calibre 16 mm 1 20 ccs ml Short barrel available Effective range with standard barrel calibre 11 mm 40 m depending on dart sizes Standard sight back sight front sight Pressure build up CO2 cartridge 16 bar or airpump 11 bar Pressure control continuous 0 10 bar Safety striker ...

Страница 4: ...void that children and other unauthorized individuals enter into possession of darts or part of darts Clean darts and part of darts contamined with drugs before disposing them Never use drugs or alcohol while handling this product Never use our applicators with pure oxygen e g oxygen cartridges Of course all regulations applicable in your country with regard of the handling of weapons as well as a...

Страница 5: ...rter 90 to the left until the guiding pin situated at the barrel retainer ring locks Individual Adjustments gun Adopt the cheek piece and the shoulder support at a position at which you can shoot comfortably Inserting of the CO cartridge Unscrew the cartridge holder and insert a CO cartridge Tighten up the cartridge holder until the cartridges is tapped Only replace open cartridges if they are com...

Страница 6: ... cause damages to your applicator Damages to material which are proven to be caused by deliberate exceeding of the maximum pressure ceases our guarantee We want to point out that also a manipulation of the safety valve immediately ceases our guarantee and in this case we do not assume any liability for damages to persons or material Loading of the dart syringe Unscrew the loading screw and insert ...

Страница 7: ...e in the position to avoid an unintended pressure built up Please check the function of your applicator if you have not used it for a longer time 7 Special equipment Here following please find a summary of our special equipment for your applicator Telescopic sight OP1 Red Dot sight OP2 Laser rangefinder RF Adaptor for cartridges 45gr Airpump FP Additional barrel 11mm for 1 5cc syringes Additional ...

Страница 8: ...e or the use of the applicator which are caused by irregular environmental conditions unprofessional use or use which is not in accordance with regulations If the points in the user and maintenance manual are not observed a guarantee claim will not be accepted 8 Should the applicator be used in another country than the country it had been developed and produced in it may be that some technical cha...

Отзывы: