SI-125 Power Amplifier Manual 

 

SI-125 

Power Amplifier Manual 

6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 

November 2016, Rev 0.5 

Phone: (905) 564-0801  Fax: (905) 564-0806  www.telecor.com 

E:\T2-108\T2-M108-ABC\T2-M108-B.doc/AD 

 
 

 

The Telecor SI-125 Power Amplifier delivers 125 watts of audio power intended to drive 
industry standard speakers for sound reinforcement and paging systems. The amplifier will 
accept either a balanced or single-ended input source. A sensitivity Input Level switch is 
provided to select either the 1 V (0 dB) or 100 mV (-20 dB) input level. Output terminals are 
provided for 4 

, 8 

, 25 V and 70 V speaker lines. The amplifier contains current limiting 

circuitry on the output to protect it from overloading. The amplifier also has circuitry to protect it 
from overheating. 

The SI-125 Power Amplifier can have optional modules installed for additional functionality. 
The PA-AM Power Amplifier Attenuator Module allows the amplifier to support a 25 V input 
signal. The PA-MM Power Amplifier Monitor Module activates a relay under normal amplifier 
operation. The PA-PM Power Amplifier Paging Module provides the amplifier with additional 
inputs for a low impedance microphone and two balanced line level inputs. 

The SI-125 Power Amplifier conforms to UL 60065 ETL listed mark with listing number 
3059290. 

The following symbols are on the amplifier and in this manual: 

 

 

CAUTION 

These servicing instructions are for use by qualified service personnel only. To reduce the risk 
of electric shock, do not perform any servicing other than that contained in the operating 
instructions unless you are qualified to do so. 

Содержание SI-125

Страница 1: ... from overloading The amplifier also has circuitry to protect it from overheating The SI 125 Power Amplifier can have optional modules installed for additional functionality The PA AM Power Amplifier Attenuator Module allows the amplifier to support a 25 V input signal The PA MM Power Amplifier Monitor Module activates a relay under normal amplifier operation The PA PM Power Amplifier Paging Modul...

Страница 2: ...ee the Troubleshooting section C CURRENT OVERLOAD Light If the current output of the amplifier exceeds its maximum power output the Current Overload light will illuminate and the output level will begin to be reduced The amplifier will continue to operate with the current limiting circuit reducing the output power If the Current Overload light illuminates see the Troubleshooting section D GAIN Con...

Страница 3: ...overs the slot Please note that the accessory modules are not user installable They must be factory installed and ordered with the amplifier Do not remove any modules or the cover plate J INPUT LEVEL Switch The Input Level switch selects the range of the input level This switch works in conjunction with the GAIN Control on the front of the amplifier The Input Level switch should be set to match th...

Страница 4: ...urn on either when there is excessive signal level on the input or when there is hard clipping present on the output The CLIP light will not turn on when the output level is clipped due to current overload Installation Before installing an SI 125 Power Amplifier carefully inspect the device for any damage that may have occurred during shipping The shipping package should contain only the Power Amp...

Страница 5: ...own in Figure 5 Figure 5 Input Connections To reduce the incidence of ground loop hum oscillation or interference from other audio sources 1 Use a shielded cable for input wiring The shield must be grounded at one end of the cable only not both 2 Regardless of what type of input signal is supplied to the amplifier balanced or single ended the GND terminal should not be connected to the common term...

Страница 6: ...pplications there is often a privacy switch in the room When this switch is activated it grounds one side of the room speaker line through a transformer Make sure that all these privacy switches are not in the Privacy position when measuring line impedance to ground These switches do not adversely affect the operation of the amplifier When measuring load impedance on a Telecor installation disconn...

Страница 7: ...registers a signal when no signal should be present The amplifier may be oscillating possibly at a very high frequency This may be caused by running input and output wires close together grounding the input or incorrect grounding of the shield The Current Overload light illuminates or flashes This indicates that the amplifier is being overloaded Check the total speaker load on the amplifier Also c...

Страница 8: ...ls on input and output Mas Con connectors are used with optional modules Controls Power Switch Illuminated GAIN Control Low Cut Switch Input Level Switch 1 V 100 mV Indicators Clip High Temperature VU Meter and Current Overload Protection Foldback current limiting Over temperature protection Primary circuit fused at 3 5 A Temperature Range 10 C to 35 C 14 F to 95 F Power Consumption AC 120 V 60 Hz...

Страница 9: ...ansportation labor charges indemnity etc are not covered by this warranty and no responsibility for same will be assumed by us Our liability does not extend to consequential damage AUTHORIZED REPAIR STATION All participating Distributors and Dealers are authorized to accept Telecor products for return to us for repair or replacement or customers may return goods to us directly providing that retur...

Отзывы: