Rev. 004
Energy 2510 D
GB
21
8.3.4 Checking the Alternator Belt
To check the belt connecting the engine to the
alternator, first of all take the generating set out
of the hood; see section 8.3.
Then screw out the suitable screws (fig. 37 ref. 1)
to remove the lid of the pulley box (fig. 37 ref. 2)
Halfway through the path between the two
pulleys, press the belt towards the middle of the
belt (fig. 38 ref. 1). Apply a pressure of 35 N (3.5
Kg)
By applying such a pressure, the belt should
move by 15 mm (fig. 38 ref. 2)
8.3.5 Adjusting the Alternator Belt
If the belt tension is not as described in section
8.3.4, it must be adjusted.
Unloose the screw of the belt tightening pulley
(fig. 39 ref. 3) and tension the belt via the
adjusting screw (fig. 39 ref. 2) according to
section 8.3.4. Tighten the belt tightening pulley
again via the suitable screw (fig. 38 ref. 3).
9 DECOMMISSIONING AND DISMANTLING
INSTRUCTIONS
Should you have to dismantle the generating set,
refer to specialised shops.
10 RECOMMENDED FIRE-FIGHTING
EQUIPMENT
In case of fire, never open the generating set
hood and use only approved type fire
extinguishers.
Never use water to put
out
flames
in
the
generating
set.
Содержание Telair ENERGY 2510D
Страница 23: ...Rev 004 Energy 2510 D GB 23 12 ENERGY 2510 D WIRING DIAGRAM...
Страница 24: ...Energy 2510 D Rev 004 24 GB 13 ENERGY 2510 D LIST OF SPARE PARTS...
Страница 25: ...Rev 004 Energy 2510 D GB 25...
Страница 26: ...Energy 2510 D Rev 004 26 GB...
Страница 27: ...Rev 004 Energy 2510 D GB 27...
Страница 28: ...Energy 2510 D Rev 004 28 GB...
Страница 42: ...Energy 2510 D Rev 004 42 GB...
Страница 43: ...Rev 004 Energy 2510 D GB 43...
Страница 44: ......