Energy 2510 D
Rev. 004
18
GB
•
Take the engine oil level dipstick out (fig. 26
and 27 ref. 1).
•
Should the oil level be below the upper notch,
restore the oil level by adding the
recommended type of engine oil using the
suitable filler cap (fig. 26 ref. 2): (refer to the
engine user and maintenance manual).
8.3 Maintenance operations to be carried out
by skilled personnel
To carry out certain servicing operations, it is
possible to extract the
generating set from the
hood.
By means of the suitable key to open the lock,
remove the front door (fig. 16 ref. 3).
Then remove the bottom surface locking screw
(fig. 16 ref. 1) on both sides.
Take out the bottom surface with the engine all
the way to the mechanical stop (fig. 17).
If you wish to completely remove the engine
surface, screw out the setscrews (fig. 16 ref. 2)
too.
This will make it easier to obtain access to all the
inside parts of the generating set for unscheduled
maintenance or repair operations.
8.3.1 Engine oil replacement
Use multigrade oil for Diesel engines having a
SAE viscosity degree suited to the climate the
generating set is working in (see table and
detailed instructions in the engine use and
maintenance manual).
To make it easier to drain the spent engine oil, it
is advisable to let the engine run for 3 to 5
minutes; in this way, the oil will be more fluid and
emptying will be quicker and more thorough.
Undo the special cap on the oil sump (fig. 28 ref.
1) and allow all the contained oil to be drained to
a collecting tank.
After doing this, screw the cap back on and
restore the oil level inside the engine sump, using
the filler cap (fig. 26 ref. 2).
Pour 1.1 l oil in the sump. Anyway, observe the
maximum level as indicated on the dipstick (fig.
27 ref. 1).
•
Hot oil can scald.
•
Causing the engine to run when the oil
level is too low can seriously damage it.
•
Check the oil level after the engine has
been turned off
.
Spent oil should not be
disposed freely in the environment but taken
to special disposal centres carrying out
disposal and/or recycling in compliance with
the applicable law provisions in force in the
country of use.
For cold
climates
For hot climates
Содержание Telair ENERGY 2510D
Страница 23: ...Rev 004 Energy 2510 D GB 23 12 ENERGY 2510 D WIRING DIAGRAM...
Страница 24: ...Energy 2510 D Rev 004 24 GB 13 ENERGY 2510 D LIST OF SPARE PARTS...
Страница 25: ...Rev 004 Energy 2510 D GB 25...
Страница 26: ...Energy 2510 D Rev 004 26 GB...
Страница 27: ...Rev 004 Energy 2510 D GB 27...
Страница 28: ...Energy 2510 D Rev 004 28 GB...
Страница 42: ...Energy 2510 D Rev 004 42 GB...
Страница 43: ...Rev 004 Energy 2510 D GB 43...
Страница 44: ......