TH-EU KVM Extender
2-15-2012
45
7.2
Interconnect Cable
7.2.1
Fiber
A point-to-point connection is necessary. Operation with multiple patch
panels is allowed. Routing over active network components, such as
Ethernet Hubs, Switches or Routers, is not allowed.
Type of Interconnect Cable
(Cable notations according to VDE)
Type of cable
Specifications
Multi-Mode 50
µ
m
One fiber 50
µ
m
I-V(ZN)H 2G50 (in-house patch cable)
I/AD(ZN)H 4G50 (in-house or outdoor
breakout cable, resistant)
Multi-Mode 62.5
µ
m
One fiber 62.5
µ
m
I-V(ZN)HH 2G62.5 (in-house breakout
cable)
A/DQ(ZN)B2Y 4G62.5 (outdoor cable,
with protection against rodents)
Maximum Acceptable Cable Length
Type of cable
Maximum Acceptable Cable Length
Multi-Mode 50
µ
m (OM3) 1,000 m (3,280 ft)
Multi-Mode 50
µ
m
400 m (1,300 ft)
Multi-Mode 62.5
µ
m
200 m (650 ft)
Type of Connector
Connector
SC Connector