background image

 

 

Model 458-LM-A1-30 

Multi-Standard Local Loop Simulator 

w/ Optional AWGN Generator

 
 

 

0315-0364 Rev. D 

Date of Publication: 06/06/2017 

 
 
 
 
 
 
 

 

 
 

 

“Results You Can Count On”

 

Содержание 458-LM-A1-30

Страница 1: ...Model 458 LM A1 30 Multi Standard Local Loop Simulator w Optional AWGN Generator 0315 0364 Rev D Date of Publication 06 06 2017 Results You Can Count On...

Страница 2: ...N Generator This one channel product simulates 26 AWG PIC as specified in T1 417 Contact Information Telephone E mail Internet General 631 423 3232 support telebytebroadband com Technical support 800...

Страница 3: ...Terms and Conditions 1 TELEBYTE INC warrants its broadband simulation equipment to be free from defects in material and workmanship under normal and proper use and in its unmodified condition for 12...

Страница 4: ...will have a 90 day warranty In those cases where no trouble is found a reduced charge will be billed to cover handling testing and packaging Whether in or out of warranty a Return Material Authorizati...

Страница 5: ...2 0 Specifications 2 1 2 1 458 LM A1 30 2 1 2 2 458 3SLB 2 1 2 3 458 CC 16 458 CM 2 2 3 0 Control 3 1 3 1 1 RS 232 Serial Port Remote Commands 3 1 3 1 2 IEEE 488 GPIB Remote Commands 3 3 3 2 Graphical...

Страница 6: ...ion allows for common or independent noise levels on both sides This 30 MHz local loop simulator is plugged into our Model 458 3SLB 3 Slot or 458 CC 16 458 CM 16 Slot chassis where settings are contro...

Страница 7: ...CPE end MODEM CPE DSLAM CO MODEM CPE DSLAM CO MODEM CPE DSLAM CO MODEM CPE DSLAM CO MODEM CPE DSLAM CO 458 LM A1 30 AWGN1 2 Variety of Configurations Local Loop Noise Combined Local Loop Noise Combine...

Страница 8: ...m Current 130 mA Connectors 2 RJ 45 s on front Optional White Noise AWGN Generator add on sub module 90 dBm Hz to 145 dBm Hz in 0 25 dBm increments 2 2 458 3SLB Product Specifications Chassis and Cont...

Страница 9: ...7U 19 in W x 22 in D x 12 22 in H 482 6 mm W x 558 8 mm D x 310 4 mm H Environmental Operating 32 F to 122 F 0 to 50 degrees C Storage 0 to 95 relative humidity non condensing Remote Control Connector...

Страница 10: ...te Commands 3 1 1 RS 232 Serial Port Remote Commands Set Length Set Length Command Values SL M LE C Where SL set length M module slot number 01 16 458 CM or 01 03 458 3SLx LE length from 0 24025 feet...

Страница 11: ...in 0 25 dBm Hz steps Examples SL 02 NOISE CPE OFF Set CPE noise source to off SL 02 NOISE CO OFF Set CO noise source to off SL 02 NOISE CO 95 00 Set CO noise source to 95 00 dBm Hz SL 02 NOISE CPE 123...

Страница 12: ...WGN Generator Page 3 3 3 1 2 IEEE 488 GPIB Remote Commands Set Length Command SETCARD LENGTH 02 24025 N Read Length Command READCARD LENGTH M Set Noise Command SETCARD LENGTH M NOISE CO V1 2 Read Nois...

Страница 13: ...Model 458 LM A1 30 Multi Standard Local Loop Simulator w Optional AWGN Generator Page 3 4 3 2 Graphical User Interface Refer to the 458 Universal GUI reference manual for more information...

Страница 14: ...16 458 CM 16 Slot Chassis using the UP or DOWN arrows on the LCD display e g when using our 3 slot chassis slot 1 top slot 2 middle slot 3 bottom Select the length for the current slot using LEFT or R...