Tele Radio T26-01 Скачать руководство пользователя страница 1

safe

smart

strong

T 26

IM-PM-TX102-EN-v03

Language: English (original)

INSTALLATION 
INSTRUCTIONS

Transmitters: T26-01,
T26-06, T26-07, T26-81

Содержание T26-01

Страница 1: ...safe smart strong T26 IM PM TX102 EN v03 Language English original INSTALLATION INSTRUCTIONS Transmitters T26 01 T26 06 T26 07 T26 81...

Страница 2: ...Tele Radio AB Datav gen 21 SE 436 32 Askim Sweden Phone 46 0 31 748 54 60...

Страница 3: ...ottom views 23 5 5 Transmitter side views 25 5 6 Display and display LEDS 28 5 7 Side buttons 29 CHAPTER 6 BOARD DESCRIPTION 30 6 1 Position of the printed circuit boards 30 6 2 Base board 32 6 3 Bott...

Страница 4: ...e 60 9 11 Set the radio inactivity timeout 61 9 12 Select a time zone 62 9 13 Register RFID tags 63 9 14 Erase RFID tags 64 9 15 Configure repeater slot ID 65 9 16 Show the device information 67 CHAPT...

Страница 5: ...ctly by radio remote control may be passed on to the end user Tele Radio AB remote controls are often built into wider applications This documentation is not intended to replace the determination of s...

Страница 6: ...ess the specific instructions and safety warnings of the end product manufacturer For battery precautions see 10 1 Battery precautions Tele Radio AB products are covered by a warranty against material...

Страница 7: ...llation configuration and operating instructions and general troubleshooting Please report any error or omission in this document as well as any improvement or amendment suggestion to td tele radio co...

Страница 8: ...oduct has a unique Serial Number SN It is important to keep this number and to use it in all communication with Tele Radio AB The serial number is written on the product label located in the battery c...

Страница 9: ...is transmitter is compatible with all transmitters and receivers in the Puma range 1 2 4 WEB CONFI GURATI ON APPLI CATI ON Transmitters can be customized using a Web Configuration App The Web Configur...

Страница 10: ...on instructions T26 Chapter 1 Introduction All information on how to use the Web Configuration App can be found in the application itself or in the corresponding documentation ED WB DX101 10 IM PM TX1...

Страница 11: ...dle the system safely The following information is intended for use as a complement to applicable local regulations and standards IMPORTANT Tele Radio AB remote controls are often built into wider app...

Страница 12: ...el Make sure the power supply is switched off before opening the receiver Failure to follow these instructions could result in death serious injury or equipment damage 2 1 2 OPERATI ON This product is...

Страница 13: ...l Keep the safety information for future reference Always download the Installation instructions from our website www tele radio com for the latest available version l If error messages are shown it i...

Страница 14: ...a load To test the stop button 1 Press the Stop button 2 Twist and release the Stop button 2 2 2 CAPACI TI VE SENSORS NOTE By default T24 1 and T24 07 are equipped with capacitive touch sensors for o...

Страница 15: ...or subsystem in a category 3 Pl d rated system then the overall system is considered to be in compliance with the lower rated category NOTE The overall achieved PL must be verified to comply with the...

Страница 16: ...Installation instructions T26 Chapter 3 Functional safety Achieved performance level PL Safety function MTTFd years DCavg Category Achieved PL Stop function 100 95 3 d 16 IM PM TX102 EN v03...

Страница 17: ...distance 6 Operating temperature 20 70 C 4 158 F Storage temperature 30 80 C 22 176 F Pairing registration Easy to pair without tools and without opening the receiver housing Bluetooth configurable o...

Страница 18: ...joystick and switch enabled IP code IP65 4 2 2 OTHER SPECI FI CATI ONS T26 01 T26 06 T26 07 T26 81 Number of joysticks 2 2 axis with spring return for analogue control directions1 Number of paddles Nu...

Страница 19: ...vement control on X Movement control on Y Movement control on Z 0x2 2 step 2x2 2 step 2 step 2x0 2 step 4x4 4 step 4 step 4x0 4 step Analog XY stepless stepless Analog Y stepless Analog XYZ stepless s...

Страница 20: ...for illustrative purposes only Depending on the configuration the actual product appearance may differ from the basic model used for reference 5 1 Overview 1 side button 2 2 side button 1 3 Status LE...

Страница 21: ...3 LCD display 4 Battery LED 5 Customizable area2 6 Belt loops 5 3 2 T26 06 1 Handlebar 2 Status LED 3 LCD display 4 Battery LED 5 Customizable area3 6 Belt loops 1With integrated LEDs 2Paddles joysti...

Страница 22: ...structions T26 Chapter 5 Product general description 5 3 3 T26 81 1 Handlebar1 2 Status LED 3 LCD display 4 Battery LED 5 Joysticks 1 2 6 Belt loops 7 Toggle switches 1 3 1With integrated LEDs 22 IM P...

Страница 23: ...5 Product general description 5 4 Transmitter bottom views 5 4 1 T26 01 T26 81 1 Key switch 2 Belt loops 3 Battery compartment 4 Stop button 5 Product label 6 RFID antenna configurable option 7 Repla...

Страница 24: ...eral description 5 4 2 T26 06 T26 07 1 Customizable area e g for a key switch 2 Belt loops 3 Battery compartment 4 Customizable area e g for the stop button 5 Product label 6 RFID antenna configurable...

Страница 25: ...apter 5 Product general description 5 5 Transmitter side views 5 5 1 T26 01 Left side Right side 1 LCD display 2 Handlebar1 3 SB1 4 SB2 5 SB4 6 SB3 7 Key switch 8 Belt loops 9 Stop button 1With integr...

Страница 26: ...l description 5 5 2 T26 06 T26 07 Left side Right side 1 LCD display 2 Handlebar1 3 SB1 4 SB2 5 SB4 6 SB3 7 Customizable area e g for a key switch 8 Belt loops 9 Customizable area e g for the stop but...

Страница 27: ...5 Product general description 5 5 3 T26 81 Left side Right side 1 SB1 2 LCD display 3 Handlebar1 4 Joysticks1 2 5 Toggle switches 1 3 6 SB2 7 SB4 8 SB3 8 Belt loops 9 Key switch 10 Stop button 1With...

Страница 28: ...ery indication Green means that the battery level is good while red indicates that the battery level is low When the battery LED turns red the battery should be changed recharged at the next convenien...

Страница 29: ...u log in etc 5 7 Side buttons The side buttons have different functions depending on the mode the transmitter is in 1 SB1 2 SB2 3 SB3 4 SB4 5 7 1 TRANSMI TTERS USI NG SOFTWARE NUMB ER SW0033 31V06 OR...

Страница 30: ...onic technicians should add and map expansion boards and inputs outputs 6 1 Position of the printed circuit boards Each board is identified by a position number When referring to a component or a conn...

Страница 31: ...boards K Circuit board for the display O RFID module P Circuit board boards for the LEDs in the handlebar Q Circuit board boards for the LEDs in the handlebar R Radio module 2 4 GHz S Bluetooth modul...

Страница 32: ...9 Connector for alternative stop button1 10 Connector for SB1 11 Connector for SB2 12 not implemented 13 Connector for A D inputs 14 Connector for A D inputs 15 Connector EXPIO for Daisy chain 16 Conn...

Страница 33: ...egrated in all T26 models It has position number B 1 Connector for standard stop button 2 Connector for battery 3 Connector for base board 4 Connector for key switch beneath 5 Connectors for cable con...

Страница 34: ...sed to increase the number of inputs outputs and communication options There are currently three expansion boards available for the T26 transmitters EXPANSION BOARDS Description Number of I Os TR408 G...

Страница 35: ...ADIG 5 Connector for daisy chain IN RX 6 Connector for DIOs 7 Connector for DIOs 8 Connector for DIOs There are three connectors for ADIG and three terminal blocks for alternative wiring of DIG NOTE V...

Страница 36: ...description J4 DIO connector J4 Pin Description 1 V_CTRLABLE 2 DIG23 3 DIG24 4 GND J5 DIO connector J5 Pin Description 1 V_CTRLABLE 2 DIG27 3 DIG28 4 GND J6 DIO connector J6 Pin Description 1 V_CTRLAB...

Страница 37: ...n OUT TX 2 Connector for paddle IOs 3 Connector for paddle IOs 4 Connector for paddle IOs 5 Connector for paddle IOs 6 Connector for daisy chain IN RX Connec tors for Paddle inputs outputs NOTE V is a...

Страница 38: ...P2 M1 3 P2 V1 8 P2 M2 4 P2 V2 9 V CTRLABLE 5 10 GND J3 Paddle connector J3 Pin Description Pin Description 1 GND 6 2 V CTRLABLE 7 P3 M1 3 P3 V1 8 P3 M2 4 P3 V2 9 V CTRLABLE 5 10 GND J4 Paddle connect...

Страница 39: ...2 Connector for A D IOs 3 Connector for A D IOs 4 Connector for A D IOs 5 Connector for daisy chain IN RX Connec tors for Analog Digital inputs outputs J1 A D connector J1 Pin Description Pin Descript...

Страница 40: ...ription J3 A D connector J3 Pin Description Pin Description 1 GND 5 AD3X2 2 AD3X1 6 AD3Z2 3 AD3Y2 7 V 5 V 4 AD3Y1 8 AD3Z1 Current c ons umption of H all Joys tic ks Joystick axis Current consumption X...

Страница 41: ...ry compartment Status LED green When started radio link established green When started no radio link red Fatal error More information can be found on the display red Sending stop logout command More i...

Страница 42: ...with the login procedure before using the system Once a transmitter has been logged in it will remain logged in until it is manually logged out More than one transmitter can be registered in the rece...

Страница 43: ...can be activated to prevent unauthorized personnel from operating the transmitter To activate the RFID functions contact your representative for assistance Once the RFID start up protection functions...

Страница 44: ...wing steps l Make sure that the controlled object can not cause any harm in the event of unexpected movement l Always follow local safety rules and start the equipment according to the corresponding i...

Страница 45: ...cedure see 9 7 Clear blocked inputs 3 Press the Select button to select one or more receiver s for the session The display shows Select one or more items and the list of the registered receivers Selec...

Страница 46: ...cally be selected the next time the transmitter is started 1 Make sure that all safety measures have been followed 2 Make sure the transmitter battery is charged 3 Make sure that the Stop button is pr...

Страница 47: ...e second The buzzer emits a beep 12 Release both Start buttons The Status LED flashes rapidly while waiting for the receiver confirmation l If the transmitter has already been logged in to the receive...

Страница 48: ...ll receivers that are part of the radio session 8 7 1 SOFTWARE VERSI ON SW0033 31V06 OR HI GHER 1 Press and hold side button SB4 2 Press the Stop button The display shows Logging out and Logout succes...

Страница 49: ...ensity Set the display luminosity in Buzzer Volume Set the buzzer volume level in Radio Inactivity Timeout Set the off delay in s before the transmitter automatically switches off Time Zone Select the...

Страница 50: ...e been activated a PIN code will always be required for accessing the Menu mode NOTE Default PIN code for the standard access level is 1234 9 2 Enter Menu mode no PIN code required 1 Make sure that th...

Страница 51: ...Menu PIN 0000 7 Enter the first digit using the Up Down buttons NOTE Once the Select button has been pressed it is not possible to move back to the previous digit Pressing the Back button will abort t...

Страница 52: ...re to be successful the receiver must be powered up RISK OF UNINTENDED EQUIPMENT OPERATION Only transmitters that are intended for use should be registered in the receiver Failure to follow these inst...

Страница 53: ...splay shows Session Selection 7 Enter Menu mode see 9 2 Enter Menu mode no PIN code required 8 Navigate to the Register menu using the Up Down buttons 9 Press the Select button to enter 10 Choose a lo...

Страница 54: ...g slow The transmitter turns off If not successfully completed On the Receiver On the Transmitter The receiver exits registration mode LED 1 is flashing red If Bluetooth has been activated the LED 5 w...

Страница 55: ...H START BUTTONS 3 Enter Menu mode see 9 2 Enter Menu mode no PIN code required 4 Navigate to the Erase menu using the Up Down buttons 5 Press the Select button to enter 6 Choose the receiver s to be e...

Страница 56: ...ceiver will automatically be stored in the same location as in the old transmitter If this location is no longer available the replacement will fail If the transmitter being replaced is registered in...

Страница 57: ...ning message Inputs have been blocked IO board 0X 0xXXXXXXXX To clear the locked inputs 1 Make sure that the Stop button is pressed 2 Turn the key switch to the On position horizontal 3 Twist and rele...

Страница 58: ...Selection 4 Enter Menu mode see 9 2 Enter Menu mode no PIN code required 5 Navigate to the Radio Channel menu using the Up Down buttons 6 Press the Select button to enter The display shows Range 11 26...

Страница 59: ...initial start up logo is displayed Battery indicator s light s The display shows Session Selection 4 Enter Menu mode see 9 2 Enter Menu mode no PIN code required 5 Navigate to the Backlight Intensity...

Страница 60: ...initial start up logo is displayed Battery indicator s light s The display shows Session Selection 4 Enter Menu mode see 9 2 Enter Menu mode no PIN code required 5 Navigate to the Buzzer Volume menu u...

Страница 61: ...ase the Stop button The initial start up logo is displayed Battery indicator s light s The display shows Session Selection 4 Enter Menu mode see 9 2 Enter Menu mode no PIN code required 5 Navigate to...

Страница 62: ...d Battery indicator s light s The display shows Session Selection 4 Enter Menu mode see 9 2 Enter Menu mode no PIN code required 5 Navigate to the Time Zone menu using the Up Down buttons 6 Press the...

Страница 63: ...m and the list showing the registered RFID tags ID numbers 7 Choose a location for the RFID tag to be registered in using the Up Down buttons 8 Press the Select button to select A sign is displayed in...

Страница 64: ...ired 5 Navigate to the Startup Protection RFID Erase menu using the Up Down buttons 6 Press the Select button to enter The display shows Select a single item and the list showing the registered RFID t...

Страница 65: ...not start the repeater config Register the transmitter in the receiver see 9 4 Register a transmitter in a receiver before proceeding with the configure repeater instruction 1 Make sure that the Stop...

Страница 66: ...ange 0 14 Value XX 9 Change the slot ID 1 14 using the Up Down buttons 10 Press the Select button to confirm The display shows Stored in repeater The transmitter turns off Go back to step 1 and try ag...

Страница 67: ...p button The initial start up logo is displayed Battery indicator s light s The display shows Session Selection 4 Enter Menu mode see 9 2 Enter Menu mode no PIN code required 5 Navigate to the Show de...

Страница 68: ...correct type l Do not short circuit disassemble deform or heat batteries l Never attempt to charge a visibly damaged or frozen battery l Do not use or charge the battery if it appears to be leaking de...

Страница 69: ...multiple batteries in the same plastic bag l Do not incinerate or dispose of batteries in fire l Do not place used batteries in the household waste Dispose of used batteries in accordance with the app...

Страница 70: ...charging error during charging the corresponding battery LED will flash red green alternatively appears orange with an interval ON 100 ms and OFF 900 ms The battery can be recharged using a Tele Radi...

Страница 71: ...batteries must be physically separated before disposal Make sure that electronics or batteries are not disposed of in household waste 10 2 1 CHARGE THE B ATTERY I N THE TAB LE CHARGER NOTE When approx...

Страница 72: ...Tele Radio AB The following are not covered by the warranty l Faults resulting from normal wear and tear l Parts of a consumable nature l Products that have been subject to unauthorized modifications...

Страница 73: ...ery and recycling please take this product to a designated collection point Tele Radio AB strives to minimize the use of hazardous materials promotes reuse and recycling and reduces emissions to air s...

Страница 74: ...ected l Consult the dealer or an experienced radio TV technician for help To satisfy FCC RF exposure requirements a separation distance of 20 cm or more should be maintained between the antenna of thi...

Страница 75: ...B ELS The radio module in this product is labeled with its own FCC ID and IC numbers The FCC ID and IC numbers are not visible when the radio module is installed inside another device Therefore the ou...

Страница 76: ...radio protocol hardware and settings Depending on the message knowledge in one or several of the areas listed below is needed l Radio protocol 2rp l Hardware 2hw l Settings manager 2sm Technical Suppo...

Страница 77: ...be stuck in busy loop r0 xxxx r1 xxxx r2 xxxx r3 xxxx r12 xxxx lr xxxx pc xxxx psr xxxx 1 MemFault 1005 A memory fault was detected while memory address xxxxxx was under test 1 SettingsApiNoFreeFlash...

Страница 78: ...is too high xxxx xxxx Requesting power cycle of I2C bus and slaves 1 AccelerometerFailedReading 1032 Failed to read data from accelerometer sensor xxxx got xxxx from i2cOperation 1 AccelerometerMaxThr...

Страница 79: ...xxxx change xxxx capSensorCountRegsFast xxxx capSensorCountRegsSlow xxxx 1 CapSensorFailedReadingSysFlags 1056 Failed to read IQS263_SYS_ FLAGS_REG from capacitive sensor xxxx got xxxx from i2cOperati...

Страница 80: ...being charged 3 ChargingCompleted 1078 Charging of battery xxxx completed 3 ChargingQualification 1079 Entering qualification charging for battery xxxx 2 ChargingStarted 1080 Charging started for bat...

Страница 81: ...U responded with malformed response to version query 1 SafetyCpuInvalidSwVersion 1145 Safety CPU has invalid SW version 1 SafetyCpuFailedToStartCommunication 1146 Safety CPU failed to start communicat...

Страница 82: ...ohibited 1165 The RF cc2520 clock was activated by CPU1 when it was not allowed to 1 SafetyErrorCPU1VsCPU2SafeDataInconsisteny 1166 CPU1 and CPU2 does not agree on the state of the safe data 1 SafetyE...

Страница 83: ...ds 1181 Unexpected number of IO boards detected expected xxxx detected xxxx 2sm IoBoardsFailedToConfigureIoBoard 1182 Failed to configure IO board with trabus address xxxx 1 IoBoardInBootloader 1183 I...

Страница 84: ...secutive errors xxxx 1 IoBoardCommunicationReset 1192 Reset of IO board communication took place 2hw IoBoardTooManyCommunicationResets 1193 Too many consecutive resets of IO board communication 2hw Io...

Страница 85: ...missmatching hw config identifier expected xxxx actual xxxx 2sm IoBoardSwIdMismatch 1202 IO board with CPU trabus address xxxx has mismatching SW id expected SW0033 xx actual SW0033 xxx 1 IoBoardFaile...

Страница 86: ...ompleteInitPhase 1210 The IO boards or main board IO on TR430 failed to complete their init phase 1 IoBoardPinsFailedDuringInit 1211 Failed init check of IO pins not in zp xxxxxx faulty sensor xxxxxx...

Страница 87: ...her will not block IO pins Alarm code xxxx arg xxxxx 2hw StartupCheckOfFuncBlockFailed 1230 Inconsistency found in settings for function blocks 2sm IncorrectSwVersionAllowed 1250 CPU with trabusAddr x...

Страница 88: ...i kelvin 3 ShutdownDueToLowTemperature 1282 Shutdown due to too low temperature xxxx centi kelvin 3 CableControlDiscoverySuccess 1290 Cable control discovery successful 3 CableControlDiscoveryNoRxFoun...

Страница 89: ...sts default settings 3 RfidTestFromCPU3 1383 CPU3 requests RFID test mode 3 RfidScanForUserTag 1384 CPU3 requests an RFID scan for a UserId Tag 1 SetBacklightIntensityFromCPU3 1385 CPU3 sets backlight...

Страница 90: ...der configuration 3 RepeaterConfigurationErrorNoRxAvailable 1396 Tried to start repeater configuration but there are no RX stored in the transmitter 3 RepeaterConfigurationErrorConfigIdIsZero 1397 Tri...

Страница 91: ...asIncorrectSwId 1551 The BT CPU has incorrect SW id SWxxxxvxxxxprexxxx 2hw sw needs to be flashed again BtWifiFailedToContactBtCpu 1552 No response from BT CPU during startup no response to bus mode c...

Страница 92: ...ted 2008 Login failed feed back offset not supported by TX RX id xxxx 2rp ErrorLoginFeedBackOffsetDuplicates 2009 Login failed RX id 1 xxxx RX id 2 xxxx has the same feed back offset xxxx 2rp ErrorLog...

Страница 93: ...tProcedureStarted 2021 Logout procedure started 3 ErrorLogoutTimeout 2030 Logout failed timeout 3 OkLogout 2031 Logout OK 3 ErrorEndSessionTimeout 2035 End session failed timeout 3 OkEndSession 2036 E...

Страница 94: ...2rp ErrorReplaceConfigIdMismatch 2059 Replace failed config ID missmatch RX id xxxx 2rp ErrorReplaceTxAlreadyRegistered 2060 Replace failed the new TX is already registered in RX id xxxx 2rp OkReplac...

Страница 95: ...transmission is complete Reset by ESD 1 SafetySwErrorProtocolSignalCorrupted 2100 The variable protocolSignal is corrupted xxxx 1 RxFeedbackStatusChanged 2110 Lost or gained feedback from one or more...

Страница 96: ...BtMcuLinkLTK 1465 Bonded link ltk xxxxxx div xxxx rand xxxxxx keySize xxxx 1 BtMcuSingingKey 1466 Bonded Singing srk xxxxxx signcount xxxxxx 1 BtMcuCfg 1467 CFG attrHandle xxxx value xxxxxx 1 BtMcuLi...

Страница 97: ...Osal event occured 1 BtMcuPherAttFlowControViolated 1477 Pheripheral AttFlowControViolated opcode xxxxxx pendingOpcode xxxxxx 1 BtMcuPherAttMTU 1478 Pheripheral mtu xxxx 1 BtMcuPherAdvUpdateDone 1479...

Страница 98: ...dex4 Osal Event Opcode index4 event xxxxxx status xxxxxx opcode xxxxxx status1 xxxxxx connectionHandle xxxxconnRole xxxxxx connInterval xxxx connLatency xxxx connTimeout xxxx clockAccuracy xxxxxx 1 Bt...

Страница 99: ...DC Diagnostic Coverage FIT Failures in time 1 FIT 1 failure per 10 9 hours HFT Hardware Fault Tolerance MTTF Mean Time To Failure PFH Probability of Failure per Hour PL Performance level SFF Safety Fa...

Страница 100: ...ty 59 Base board 32 Battery 70 Charge 71 BATTERY PACK 70 Battery precautions 68 Handling 68 Storage 68 Boards 30 Bottom board 33 Buzzer volume 60 C Capacitive sensors 14 Channel number 58 CHARGERS 70...

Страница 101: ...ion 17 D Data format 17 device information 67 Dimensions 20 Display LEDs 28 Display specifications 18 Disposal 69 E EIRP 17 Erase 55 Expansion boards 34 Extra I Os 35 Hall efect joysticks 39 Paddle I...

Страница 102: ...Log out 48 M M245060 70 M769746 70 M769755 70 M769780 70 Maintenance 72 Menu mode 49 Enter Menu menu no PIN code 50 Menu protection 50 Menu navigation 42 Message categories 41 Message types 28 N Numb...

Страница 103: ...Radio frequency output power 17 Radio module 75 Range 17 Register 52 Repeater Configure 65 Replace 56 RFID tags Erase 64 Register 63 S Safety Features 14 Safety standards 18 Select a Radio frequency 5...

Страница 104: ...sages 41 Stop button 14 Stop function 14 Stop relays 14 Storage temperature 17 Battery 70 Switch off 48 System address 17 T Time zone 62 Transmitter display 28 W Warnings restrictions 11 Installation...

Страница 105: ...Installation instructions T26 This page intentionally left blank IM PM TX102 EN v03 105...

Страница 106: ...safe smart strong These Installation instructions are subject to change without prior notice Download the latest Installation instructions from www tele radio com...

Отзывы: