• Configure the Ethernet interface on the IP terminal (normally a PC) using the IP address from the following range
[192.168.1.2, 192.168.1.254] and mask 255.255.255.0. E.g. 192.168.1.2, 255.255.255.0.
• Connect the IP terminal’s Ethernet interface to any of the Ethernet Switch ports on the Teldat H2 Automotive (the
LAN1...4 connectors) through the Ethernet cable (RJ45) provided.
• Start a Telnet session from the IP terminal to IP address 192.168.1.1 (the Teldat H2 Automotive default address).
• The default configuration does not ask for login credentials (user/password) to access the console.
A.4 Connectors
A.4.1 LAN connector
RJ45 LAN
RJ45 PIN
FE Signals
GE Signals
1
2
3
4
5
6
7
8
BI-DA+
BI-DA-
BI-DB+
--
--
BI-DB-
--
--
BI-DA+
BI-DA-
BI-DB+
BI-DC+
BI-DC-
BI-DB-
BI-DD+
BI-DD-
A.4.2 WWAN connectors
PIN
ANT
Internal
External
RF in/out
GND
A.4.3 WLAN connectors
PIN
ANT
Internal
External
RF in/out
GND
Teldat S.A.
Technical Information
Teldat H2 Automotive Router
33