background image

 

TELCO FABRIKKER AS 

N.7580 Selbu, Norge 

Phone + 47 73 81 20 90   Fax: +47 73 81 74 95   e-mail: [email protected]

 

 

 

 

 

 

Installation instructions for marine heater T2RIB 

The heater must only be installed by authorized electricians. 

1.

 

Fasten the heater to the wall. Screws are provided 

2.

 

Remove the thermostat knob and the front cover of the distribution box. 

3.

 

Connect to a 4-pole terminal. 

4.

 

Connect the earth lead to the earth sign on terminal. 

5.

 

Replace the front cover and put the thermostat knob back in place 

 

Installation distance requirements: 

Minimum distance to side wall:                                  2,0 cm. 
Minimum distance to floor:                                         2,0 cm. 
Minimum distance to roof or window sill:                38,0 cm. 

 

The heater must not be located immediately below a socket outlet. 

Heaters used in bathrooms must be installed so that switches and other controls cannot be touched by a person in the bath or shower. 

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of 
experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person 
responsible for their safety.   

Children should be supervised to ensure that they do not play with the appliance 

WARNING: In order to avoid overheating, do not cover the heater. 

 

Type 

Power 

L

L

Height incl. grille 

T2RIB 025 

250 W 

96 mm. 

Min. 20 mm. 

379 mm. 

285 mm. 

150 mm. 

238  mm. 

T2RIB 03 

300 W 

96 mm. 

Min. 20 mm. 

379 mm. 

285 mm. 

150 mm. 

238  mm. 

T2RIB 04 

400 W 

96 mm. 

Min. 20 mm. 

379 mm. 

285 mm. 

150 mm. 

238  mm. 

T2RIB 05 

500 W 

96 mm. 

Min. 20 mm. 

474 mm. 

380 mm. 

150 mm. 

238  mm. 

T2RIB 08 

800 W 

96 mm. 

Min. 20 mm. 

629 mm. 

535 mm. 

150 mm. 

238  mm.

 

T2RIB 10 

1000 W 

96 mm. 

Min. 20 mm. 

869 mm. 

775 mm. 

150 mm. 

238  mm.

 

T2RIB 12 

1200 W 

96 mm. 

Min. 20 mm. 

869 mm. 

775 mm. 

150 mm. 

238  mm.

 

T2RIB 16 

1600 W 

96 mm. 

Min. 20 mm. 

1134  mm. 

1040 mm. 

150 mm. 

238  mm.

 

T2RIB 20 

2000 W 

96 mm. 

Min. 20 mm. 

1395 mm. 

1295 mm. 

150 mm. 

238  mm.

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Отзывы: