SG 14 - USER MANUAL
Space Guard Series
Photoelectric light curtains for automatic doors
Website: www.telcosensors.com
Warning
V 1.6.CD Part Number: 0666220707
E-Mail: [email protected]
This device is not to be used for Personnel Protection in Machine
Guarding Safety applications. This device does not include the self-
checking redundant circuitry necessary to allow its use in personnel
machine guarding stand-alone safety applications.
April 2019 edition
Made in Denmark
Telco A/S reserves the right to make changes without prior notice
tel
EN
Product Data
Electrical Data
SGT (Transmitter)
SGR (Receiver)
Supply voltage
12 – 36 Vdc
Max. Voltage ripple
15% (within supply range)
Reverse polarity protected
Yes
Max. current consumption
70 mA (RMS)
50 mA
Max. output load
-
200 mA
Short circuit protected
-
Yes
Inductive load protection
-
Yes
Environmental Data
Light immunity @ 5º incidence
> 100.000 lux
Temperature, operation
-20 to + 65 ºC
Sealing class
IP67
Approvals
Available Models
Model
Output
Blanking
Function
Output
Mode
Sensing
Range
Transmitter SGT 14-xxx-0xx-A1-x-0x-xx
-
-
-
C profile:
1 – 10m
D profile:
1 – 7.5 m
Receiver
SGR 14-xxx-0xx-A1-x-08-xx
Solid
State
Relay
On / Off
N.O.
SGR 14-xxx-0xx-A1-x-09-xx
N.C.
Connection
Wiring Diagrams
5 pole M12 male connector
Transmitter Model
Black wire
connected to ( - )
Black wire
not connected
Black wire
connected to ( + )
SGT 14-xxx-0xx-A1-x-
00
-xx TX is not transmitting
TX is transmitting
TX is transmitting
SGT 14-xxx-0xx-A1-x-
01
-xx TX is not transmitting
TX is transmitting
TX is not transmitting
SGT 14-xxx-0xx-A1-x-
02
-xx TX is transmitting
TX is not transmitting
TX is transmitting
Transmitter SGT 14
Receiver SGR 14 with solid state
relay used as NPN output
Receiver SGR 14 with solid state relay
used as PNP output
Receiver SGR 14 with solid state relay output.
Installation & Adjustments
Installation and Adjustment
No initial set up or adjustments are required, due the automatic signal-tracking (AST) feature,
which automatically adjust each individual channel on the system.
Notice that the SG14 system must not be placed on moving doors.
1
Mount the transmitter (SGT) and receiver (SGR) facing each other and correctly
aligned. Telco recommends that the rails are placed at least 5mm from edges for
mechanical protection.
2
Wire the sensor according to the wiring diagram. Make sure the load does not
exceed 200 mA.
3
Check for correct wiring. Select blanking function if required.
4
Turn power on.
5
The status indicator (red LED) on the SGR will flash quickly when the AST is active.
6
When the power on indicators (green LEDs) are on, the system is operating.
If the Status indicator (red LED) is constant on the SGR cannot see the SGT.
7
Notice that the rails must not be moved after the power to the SGR is turned on.
Output Logic
Detection
Output mode
Output
status
Output indicator
(yellow led)
Present
Dark operated
(N.O.)
Closed
On
Light operated
(N.C.)
Open
Off
Absent
Dark operated
(N.O.)
Open
Off
Light operated
(N.C.)
Closed
On
Indicator LEDs
Indicators
Red LED:
Status indicator
Yellow LED:
Output indicator
Green LED:
Power on indicator
Troubleshooting
Troubleshooting
Probable Reason
Corrective Action
1. Symptom: Status indicator (Red LED) on SGR is constant on.
TX is not emitting
Check supply and cable to the SGT
SGT is disabled
Enable the SGT
The lowest beam is blocked
Remove obstruction
2. Symptom: Output indicator (Yellow LED) is flashing
Severe electrical interference
Remove SGR and SGT supply cable from high
voltage cables
Severe ambient light
Change position of SGT and SGR
Cross talk from another light curtain
Change position of SGT and SGR
SGR
Output Response Time
Output Response Time
Nº of channels
16
24
32
40
48
56
Response time (max)
For obstruction by objects
larger than 100 mm.
24 ms
24 ms
30 ms
37 ms
43 ms
49 ms
SGT Test Input
SGT Test Input
The transmitter can be externally disabled and enabled via the control wire (black wire) for test
purposes. To activate the test input, please refer to “Transmitter Model” table.
Make sure no object is present in the detection area when transmitter is disabled for test.
When the transmitter is disabled, the receiver will change its output.
The test input on SGT14 has to be activated a certain minimum time T
r
in order to ensure that
the output of SG14 will switch.
On activation of the SGT14 test input, the output of the receiver will switch within a certain
maximum time T
ON
.
When the test input of SGT14 is deactivated the output will be switched back within a certain
maximum time T
OFF
.
The time T
r
is longer than T
ON
in order to ensure a complete test cycle of minimum duration.
Note:
Refer to “SGT test input response time table” & graph.
SGR Dynamic Blanking Function
Dynamic Blanking Function
All channels can be blanked without switching the output by moving a non transparent object
between the SGR and SGT from top of the rails and down to the lowest channel in one
movement.
All channels will stay blanked as long as the lowest channel at the bottom of the rails is
obstructed. Make sure that the lowest channel is well obstructed when all the channels are
blanked.
Minimum speed of the blanking object
0.05 m/s
Maximum speed of the blanking object
1.6 m/s
There is no restriction on maximum speed when removing the object.
Note:
Refer to “SGR blanking function response time” & graph.
Channel spacing
46 mm
Minimum size of blanking object
55 mm
1
2
3
4
5
1: Brown
2: White
3: Blue
4: Black
5: Black or Yellow/green
!