www.tekvox.com
1201-MV
79033-MV User Manual
Command Description
Command Example and Feedback
503
xx
Set the delay time to send CEC, RS232 and
standby commands after input signal removed
xx
= 00 ~ 30 (min) (Default: 10min)
503
xx
(
xx
= 00 ~ 30)
50887
Get the delay time to send CEC, RS232 and
standby commands after input signal removed
503
xx
(
xx
= 00 ~ 30)
50974
Send “Display On” command
50974
50975
Send “Display Off” command
50975
508
xx
Set the number of times to send Display Off
command
xx
= 88: Send command once
xx
= 89: Send command twice
50888 ~ 50889
50890
Get the number of times of sending Display Off
command
50888 ~ 50889
504
xx
Set the delay time of sending Display Off
command
xx
= 01 ~ 10(s)
504
xx
(
xx
= 01 ~ 10)
50891
Get the delay time of sending Display Off
command
504
xx
(
xx
= 01 ~ 10)
505
xx
Set the delay time of sending Display Input
Select command
505
xx
= 01 ~ 10 (s) (Default: 3)
505
xx
(
xx
= 01 ~ 10)
50892
Get the delay time of sending Display Input
Select command
505
xx
(
xx
= 01 ~ 10)
509
xx
Set multiview mode
xx
= 01 ~ 12
01
–
1 WINDOWS Full
02
–
2 WINDOWS PBP
03
–
3 WINDOWS 2U1D
04 - 4 WINDOWS SAME SIZE
05 - 2 WINDOWS PIP LU
06 - 2 WINDOWS PIP LD
07 - 2 WINDOWS PIP RU
08 - 2 WINDOWS PIP RD
09 - 4 WINDOWS PBP 3L1R
10 - 4 WINDOWS PBP 1L3R
11 - 4 WINDOWS PBP 3U1D
12 - 4 WINDOWS PBP 1U3D
509
xx
(
xx
= 01 ~ 12)