![Tektronix WFM4000 Series Скачать руководство пользователя страница 48](http://html.mh-extra.com/html/tektronix/wfm4000-series/wfm4000-series_user-manual_1078259048.webp)
Checking Gamut
Checking Gamut
Signals that are legal and valid in one signal representation may not be legal in another representation. Speci
fi
cally, signals
which are legal in the Digital YCbCr representation may not be legal if transcoded to RGB or encoded to NTSC/PAL.
Any signal that fails this test is considered outofgamut.
Your instrument supports multiple displays and alarms to detect outofgamut signals. The displays and their uses are as
follows:
Diamond for checking that SDI signals conform to legal RGB gamut space
Split Diamond separates the upper and lower diamonds to show excursions below black; otherwise it is identical to
the Diamond display
Arrowhead for checking if an SDI signal is legal for composite color space
Diamond, Split Diamond, and Arrowhead have adjustable thresholds. If the signal goes outside the area de
fi
ned by the
thresholds, the signal is outofgamut. If these limits are exceeded, the instrument can generate alarms if con
fi
gured to do so.
Setup for Gamut Checks
1.
Connect a video signal and terminate it
properly.
2.
Select the input corresponding to the
signal connected.
3.
Press and hold the
GAMUT
button
to display the signal and the GAMUT
pop-up menu.
32
WFM4000 and WFM5000 Waveform Monitors User Manual
Содержание WFM4000 Series
Страница 1: ...x WFM4000 and WFM5000 Waveform Monitors ZZZ User Manual P077243802 077 2438 02 ...
Страница 2: ......
Страница 3: ...WFM4000 and WFM5000 Waveform Monitors ZZZ User Manual xx Revision A www tektronix com 077 2438 02 ...
Страница 6: ......
Страница 16: ...Preface x WFM4000 and WFM5000 Waveform Monitors User Manual ...
Страница 76: ...Upgrading Instrument Software 60 WFM4000 and WFM5000 Waveform Monitors User Manual ...