xx
Safety Summary
Review the following safety precautions to avoid injury and
prevent damage to this product or any products connected to it.
To avoid potential hazards, use this product only as speci
fi
ed.
Retain product literature.
Retain the original product
information for future reference.
To Avoid Fire or Personal Injury
Do not operate with suspected failures.
If you suspect there
is damage to the battery, charger, or power supply, have it
inspected by quali
fi
ed service personnel.
Recharge battery pack properly.
Recharge the battery pack
only for the recommended charge cycle at the recommended
temperature.
Replace battery pack properly.
Replace the battery pack only
with the speci
fi
ed type and rating.
Use proper battery charger.
Use only the WFM2200 waveform
monitor or the WFM200BC battery charger to charge the
WFM200BA battery pack.
Do not operate in wet/damp conditions.
Do not operate in an explosive atmosphere.
Keep product surfaces clean and dry.
Safety Terms in This Manual
CAUTION.
These statements identify conditions or practices
that could result in damage to the equipment or other
property.
Safety Symbols and Terms on the Product
DANGER indicates an injury hazard immediately accessible as
you read the marking.
WARNING indicates an injury hazard not immediately
accessible as you read the marking.
CAUTION indicates a hazard to property including the product.
Battery Recycling
This WFM200BA Lithium-Ion rechargeable battery pack must
be recycled or disposed of properly.
Lithium-Ion batteries are subject to disposal and recycling
regulations that vary by country and region. Always check
and follow your applicable regulations before disposing
of any battery. Contact Rechargeable Battery Recycling
Corporation (www.rbrc.org) for U.S.A. and Canada, or
your local battery recycling organization.
Many countries prohibit the disposal of waste electronic
equipment in standard waste receptacles.
Place only discharged batteries in a battery collection
container. Use electrical tape or other approved covering
over the battery connection points to prevent short circuits.
This symbol indicates that this product complies
with the applicable European Union requirements
according to Directives 2002/96/EC and 2006/66/EC
on waste electrical and electronic equipment
(WEEE) and batteries. For information about
recycling options, check the Support/Service section
of the Tektronix Web site (www.tektronix.com).
Lithium-Ion Battery Transportation
The capacity of the Lithium-Ion rechargeable battery pack in
this product is under 100 Wh. The lithium equivalent content
has been shown to meet the applicable requirements as de
fi
ned
by the UN Manual of Tests and Criteria Part III Subsection 38.3.
Always check all applicable local, national, and
international regulations before transporting a Lithium-Ion
battery.
Transporting an end-of-life, damaged, or recalled battery
may, in certain cases, be speci
fi
cally limited or prohibited.
The battery pack must be adequately protected against
short-circuit or damage during transport.
Description
The WFM200BA rechargeable battery pack is intended for use
only with the Tektronix WFM2200 SD/HD/3G SDI Waveform
Monitor & Generator. The battery pack consists of an array
of Lithium-Ion battery cells.
When the battery is installed, an internal circuit monitors the
charge on the battery and reports the condition to either the
WFM2200 waveform monitor or the WFM200BC External
Battery Charger.
When the battery is not installed, you can check the battery
charge level by pressing the Check button on the back of the
battery pack. LEDs illuminate to indicate the amount of charge
in increments of approximately 20%.
Battery Pack Installation
NOTE.
For optimum performance, charge the battery pack
completely before using it for the
fi
rst time or after prolonged
storage.
The battery can be installed, removed, or replaced while the
instrument is turned on and operating with the AC adapter.
1.
On the rear panel of the instrument, remove the cover for
the battery compartment:
a.
Lift up the battery cover ring.
b.
Turn the battery cover ring
¼
turn counterclockwise.
c.
Lift away the battery cover.
2.
Insert the WFM200BA battery pack into the battery
compartment as shown below.
3.
Secure the battery pack tab as shown below.
4.
Replace the battery compartment cover:
a.
Insert the three tabs on the battery cover into the
chassis slots as shown below.
b.
Close the battery cover and turn the battery cover ring
¼
turn clockwise to secure the cover.
c.
Press the battery cover ring down so that it latches
into place as shown below.
Battery Maintenance Guidelines
The WFM200BA Lithium-Ion rechargeable battery pack
requires routine maintenance and care in its use and handling.
Be sure to use the following guidelines to safely use the
WFM200BA Lithium-Ion batteries and achieve the maximum
battery life span.
Battery Pack Considerations
Do not leave a battery unused for an extended period of time,
either in the product or in storage. When a battery has been
unused for six months, check the charge status, and charge or
dispose of the battery as appropriate. See
Charging the Battery
Pack
and
Battery Recycling
.
The typical estimated life of a Lithium-Ion battery is about two
to three years, or 300 to 500 charge cycles, whichever occurs
fi
rst. One charge cycle is a period of use from fully charged, to
fully discharged, and fully recharged again. You should expect
a two to three year life expectancy for batteries that do not run
through complete charge cycles.
A rechargeable Lithium-Ion battery has a limited life and
will gradually lose its capacity to hold a charge. This loss of
capacity (aging) is irreversible. As the battery loses capacity,
the length of time it will power the product (run time) decreases.
A Lithium-Ion battery continues to slowly discharge
(self-discharge) when not in use or while in storage. You need
to routinely check the charge status of the battery.
Use the WFM200BA battery pack only in WFM2200
waveform monitor. Use only WFM200BA battery packs in
your WFM2200 waveform monitor.
WFM200BA
Rechargeable Battery Pack
ZZZ
Instructions
x
*P075104101*
075-1041-01