4
Equipment may not meet the immunity requirements of this standard when test
leads and/or test probes are connected due to coupling of electromagnetic
interference onto those leads/probes. To minimize the in
fl
uence of
electromagnetic interference, minimize the loop area between the unshielded
portions of signal and associated return leads, and keep leads as far away as
possible from electromagnetic disturbance sources. Twisting unshielded test
leads together is an effective way to reduce loop area. For probes, keep the
ground return lead as short as possible and close to the probe body. Some
probes have accessory probe tip adapters to accomplish this most effectively.
In all cases, observe all safety instructions for the probes or leads used.
5
Test port noise
fl
oor can degrade to -70 dBm when the instrument is subjected
to electromagnetic interference per the IEC 61000-4-3 test. The degradation
will be at the speci
fi
c frequencies of the interfering signals.
Australia / New Zealand Declaration of Conformity – EMC
Complies with the EMC provision of the Radiocommunications
Act per the following standard, in accordance with ACMA:
EN 61326-1 and EN 61326-2-1 Radiated and Conducted
Emissions, Class A.
Equipment type
Test and measuring equipment.
Pollution degree description
A measure of the contaminants that could occur in the
environment around and within a product. Typically the
internal environment inside a product is considered to be the
same as the external. Products should be used only in the
environment for which they are rated.
Pollution Degree 2. Normally only dry, nonconductive
pollution occurs. Occasionally a temporary conductivity
that is caused by condensation must be expected. This
location is a typical of
fi
ce/home environment. Temporary
condensation occurs only when the product is out of
service.
Pollution degree rating
Pollution Degree 2 (as de
fi
ned in IEC 61010-1). Rated for
indoor, dry location use only.
Mains overvoltage category rating (AC adapter)
Overvoltage Category II (as de
fi
ned in IEC 61010-1).
Power source speci
fi
cations
Characteristic
Description
AC input voltage
100 V AC — 240 V AC
47 Hz — 63 Hz
DC power output
4.75 V — 5.25 V
VNA power consumption
<16 W
Environmental considerations
Environmental speci
fi
cations
Characteristic
Description
Temperature Range
Operating
5 °C to +50 °C
Non-operating
–40 °C to +71 °C
Humidity
Temperature
Range
Relative
Humidity
+10 °C to +30 °C
5% to 80% RH
+30 °C to +40 °C
5% to 75% RH
Operating
(non-condensing)
+40 °C to +50 °C
5% to 45% RH
Altitude
Operating
3000 meters
Non-operating
4600 meters
Product end-of-life handling
Observe the following guidelines when recycling an instrument
or component:
Equipment recycling.
Production of this equipment required
the extraction and use of natural resources. The equipment may
contain substances that could be harmful to the environment or
human health if improperly handled at the product’s end of life.
To avoid release of such substances into the environment and
to reduce the use of natural resources, we encourage you to
recycle this product in an appropriate system that will ensure
that most of the materials are reused or recycled appropriately.
This symbol indicates that this product complies
with the applicable European Union requirements
according to Directives 2012/19/EU and
2006/66/EC on waste electrical and electronic
equipment (WEEE) and batteries. For information
about recycling options, check the Tektronix Web
site (www.tek.com/productrecycling).
Front panel
No.
Component
Description
1
RF Port 1
N-type 50
Ω
female test port for
device-under-test (DUT) connection.
Use either RF port for stimulus source or
response receiver.
2
LO A
SMA 50
Ω
female port 10 dBm, 0 V DC
(reserved for future use)
3
LED
Indicator
Indicates whether the VNA is powered
and disconnected (red) or connected
(green).
4
LO B
SMA 50
Ω
female port 10 dBm, 0 V DC
(reserved for future use)
5
RF Port 2
N-type 50
Ω
female test port for
device-under-test (DUT) connection.
Use either RF port for stimulus source or
response receiver.
Rear panel
No.
Component
Description
1
Bias 2
Provides bias input for RF port 2
2
Aux Sync
50
Ω
female BNC connector (reserved
for future use)
3
Trigger In
50
Ω
female BNC connector to connect
an external device to provide a trigger
input
4
USB 2.0
Connect USB 2.0 cable
5
4.75V—5.25V
DC
DC input for the instrument
6
Ref In
50
Ω
female BNC connector to provide
optional 10 MHz reference input
7
Ref Out
50
Ω
female BNC connector to provide
10 MHz reference output
8
Bias 1
Provides bias input for RF port 1
Copyright © Tektronix, Inc. All rights reserved.