![Tektronix TPS2012B Скачать руководство пользователя страница 133](http://html1.mh-extra.com/html/tektronix/tps2012b/tps2012b_user-manual_1078406133.webp)
Reference
Measure
Push the
Measure
button to access automatic measurements. There are eleven
types of measurements available. You can display up to
fi
ve at a time.
Push the top option button to display the Measure 1 Menu. You can choose the
channel on which to take a measurement in the Source option. You can choose the
type of measurement to take in the Type option. Push the Back option button to
return to the Measure Menu and display the selected measurements.
Key Points
Taking Measurements.
You can display up to
fi
ve automatic measurements at a
time. The waveform channel must be on (displayed) to make a measurement.
Automated measurements cannot be taken on reference waveforms, or while
using XY or scan mode. The measurements update about two times per second.
Measurement type
De
fi
nition
Freq
Calculates the frequency of the waveform by measuring the
fi
rst cycle
Period
Calculates the time of the
fi
rst cycle
Mean
Calculates the arithmetic mean amplitude over the entire record
Pk-Pk
Calculates the absolute difference between the maximum and
minimum peaks of the entire waveform
Cyc RMS
Calculates a true RMS measurement of the
fi
rst complete cycle of
the waveform
Min
Examines the entire 2500 point waveform record and displays the
minimum value
Max
Examines the entire 2500 point waveform record and displays the
maximum value
Rise Time
Measures the time between 10% and 90% of the
fi
rst rising edge of
the waveform
Fall Time
Measures the time between 90% and 10% of the
fi
rst falling edge of
the waveform
Pos Width
Measures the time between the
fi
rst rising edge and the next falling
edge at the waveform 50% level
Neg Width
Measures the time between the
fi
rst falling edge and the next rising
edge at the waveform 50% level
None
Does not take any measurement
When the
Save/Recall
►
Save All
►
Print Button
option is set to Prints, you
can push the
print button to send the screen image to a printer or computer.
You can set up the oscilloscope to send a screen image to your printer through the
Utility
►
Options
►
Printer Setup
menu. (See page 72,
TPS2000B Series Digital Oscilloscope User Manual
107
Содержание TPS2012B
Страница 1: ...xx TPS2000B Series Digital Storage Oscilloscope ZZZ User Manual P071273302 071 2733 02...
Страница 2: ......
Страница 3: ...TPS2000B Series Digital Storage Oscilloscope ZZZ User Manual xx www tektronix com 071 2733 02...
Страница 8: ......
Страница 22: ...Compliance information xiv TPS2000B Series Digital Oscilloscope User Manual...
Страница 26: ...Preface xviii TPS2000B Series Digital Oscilloscope User Manual...
Страница 40: ...Getting Started 14 TPS2000B Series Digital Oscilloscope User Manual...
Страница 93: ...Math FFT TPS2000B Series Digital Oscilloscope User Manual 67...
Страница 96: ...Math FFT 70 TPS2000B Series Digital Oscilloscope User Manual...
Страница 170: ...Appendix D Cleaning 144 TPS2000B Series Digital Oscilloscope User Manual...
Страница 184: ...Index Z Zoom 58 FFT 68 Horiz menu 104 Window Zone 104 105 158 TPS2000B Series Digital Oscilloscope User Manual...