TDS1000B/TDS2000B, TDS1000C-EDU/TDS2000C, and TPS2000B Series

Digital Storage Oscilloscope

ZZZ

Declassi

fi

cation and Security Instructions

xx

www.tektronix.com

077-0445-00

Содержание TDS1001B

Страница 1: ...TDS1000B TDS2000B TDS1000C EDU TDS2000C and TPS2000B Series Digital Storage Oscilloscope ZZZ Declassification and Security Instructions xx www tektronix com 077 0445 00...

Страница 2: ...and pending Information in this publication supersedes that in all previously published material Specifications and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tek...

Страница 3: ...Preface iii Clear and Sanitize Procedures 1 Memory Devices 2 Data Export Devices 5 Troubleshooting 7 How to Clear or Sanitize a Nonfunctional Instrument 7 TDS1000B TDS2000B TDS1000C EDU TDS2000C and...

Страница 4: ...Table of Contents ii TDS1000B TDS2000B TDS1000C EDU TDS2000C and TPS2000B Series...

Страница 5: ...rument If you have any questions contact the Tektronix Technical Support Center at www tektronix com support Reference The procedures in this document are written to meet the requirements specified in...

Страница 6: ...nual name Tektronix part number TDS1000B and TDS2000B Series Digital Storage Oscilloscope Service Manual 071 1828 XX TDS2000C and TDS1000C EDU Series Digital Storage Oscilloscope Service Manual 077 04...

Страница 7: ...ll supplied to the instrument For the purpose of clearing data putting the instrument in Standby mode does not qualify as powering off For these products you will need to either push a rear panel OFF...

Страница 8: ...Preface vi TDS1000B TDS2000B TDS1000C EDU TDS2000C and TPS2000B Series...

Страница 9: ...stem resources modify the data The user cannot modify the data User accessible This column indicates whether the user can retrieve the device contents Yes The user can directly retrieve the memory dev...

Страница 10: ...gs No Indirect Firmware operations Main Acquisition board TDS models only No Remove power from the instrument for at least 20 seconds Remove power from the instrument for at least 20 seconds Real time...

Страница 11: ...in user data or settings Cleaning would disable instrument functionality Not applicable does not contain user data or settings Sanitizing would disable instrument functionality Clear Flash Procedure T...

Страница 12: ...e front of the oscilloscope For TPS oscilloscopes insert a compact flash card into the Compact Flash slot on the front of the oscilloscope 14 Push the front panel UTILITY button 15 Push the Options op...

Страница 13: ...strument setups Directly Save Front panel Files can be deleted or overwritten on the oscilloscope or a PC USB flash drive can be removed and destroyed The USB host port cannot be disabled USB device p...

Страница 14: ...Clear and Sanitize Procedures 6 TDS1000B TDS2000B TDS1000C EDU TDS2000C and TPS2000B Series...

Страница 15: ...regarding handling or disposal of the board Compact Flash Card TPS oscilloscopes only Remove the compact flash card and return the instrument to Tektronix for repair After removal of the compact flas...