Adjustments
Adjustments
The procedures that follow describe adjustments to the probe to bring the DC gain accuracy performance within the warranted
speci
fi
cations.
Equipment Required & Setup
Refer to the equipment list and the DC gain accuracy procedure in the
Performance Veri
fi
cation
to set up the equipment. You
also need the tools listed below to complete the adjustments.
Table 7: Adjustment tools
Item
Description
Tektronix part number
Release tool
Compensation box cover removal tool
003-1383-xx
Adjustment tool
Insulated, slotted (straight) head
003-1433-xx
CAUTION.
To avoid ESD damage to the probe, use an antistatic wrist strap and work at a static-approved workstation when
handling the probe
TCP202A Current Probe Instruction Manual
57
Содержание TCP202A
Страница 1: ...x TCP202A 50 MHz 15 A AC DC Current Probe ZZZ Instruction Manual P071300300 071 3003 00...
Страница 2: ......
Страница 6: ......
Страница 10: ...Table of Contents iv TCP202A Current Probe Instruction Manual...
Страница 62: ...Specifications Figure 2 Typical input impedance versus frequency 42 TCP202A Current Probe Instruction Manual...
Страница 63: ...Specifications Figure 3 Maximum peak pulse versus pulse width TCP202A Current Probe Instruction Manual 43...
Страница 65: ...Specifications Figure 4 Probe dimensions TCP202A Current Probe Instruction Manual 45...