Controls and Indicators
Menu-Driven Probe Functions
The following probe functions are available through menu screens on many Tektronix oscilloscopes. An MSO/DPO4000 series
oscilloscope is used in these examples.
Fine Scale.
This feature allows you to adjust
the vertical mA/div setting to a custom scale
that is between the
fi
xed 1–2–5 scales on many
oscilloscopes.
For example, to display a 320 mA signal over
exactly 8 vertical divisions (40 mA/div),
fi
rst set
the
fi
xed scale to 50 mA/div. Next, select Fine
Scale from the lower-bezel menu and then use
the Multipurpose knob to adjust the Fine Scale
down to 40 mA/div, as displayed on-screen.
Offset and Position.
Each of these
selections allow you to adjust that parameter
and to return the value to zero by pressing a
side-bezel button.
20 A Current Probes Instruction Manual
17
Содержание TCP0020
Страница 1: ...x TCP0020 TCP2020 50 MHz 20 Amp AC DC Current Probes ZZZ Instruction Manual P071300200 071 3002 00...
Страница 2: ......
Страница 6: ......
Страница 10: ...Table of Contents iv 20 A Current Probes Instruction Manual...
Страница 22: ...Compliance Information xvi 20 A Current Probes Instruction Manual...
Страница 80: ...Specifications Figure 2 Typical insertion impedance versus frequency 56 20 A Current Probes Instruction Manual...
Страница 81: ...Specifications Figure 3 Maximum peak pulse versus pulse width 20 A Current Probes Instruction Manual 57...
Страница 83: ...Specifications Figure 4 Mechanical dimensions 20 A Current Probes Instruction Manual 59...