Tektronix P7240 Скачать руководство пользователя страница 1

User Manual

P7240

4 GHz 5X Active Probe
071-0759-03

Warning

The servicing instructions are for use by qualified
personnel only. To avoid personal injury, do not
perform any servicing unless you are qualified to
do so. Refer to all safety summaries prior to
performing service.

Содержание P7240

Страница 1: ...obe 071 0759 03 Warning The servicing instructions are for use by qualified personnel only To avoid personal injury do not perform any servicing unless you are qualified to do so Refer to all safety s...

Страница 2: ...pending Information in this publication supercedes that in all previously published material Specifications and price change priviledges reserved Tektronix Inc P O Box 500 Beaverton OR 97077 TEKTRONI...

Страница 3: ...other locations This warranty shall not apply to any defect failure or damage caused by im proper use or improper or inadequate maintenance and care Tektronix shall not be obligated to furnish servic...

Страница 4: ......

Страница 5: ...the probe ground from the circuit under test before disconnecting the probe from the measure ment instrument Observe All Terminal Ratings To avoid fire or shock hazard observe all ratings and marking...

Страница 6: ...ments identify conditions or practices that could result in damage to this product or other property Terms on the Product These terms may appear on the product DANGER indicates an injury hazard immedi...

Страница 7: ...Operating Basics 17 Handling the Probe 17 Maximum Nondestructive Input Voltage 17 Input Linear Dynamic Range 17 Ground Lead Length 18 Ground Lead Inductance 18 Helpful Hints 21 Low inductance Groundi...

Страница 8: ...tations 16 Figure 5 Waveform distortion from ground lead length 18 Figure 6 Ground Lead Equivalent Circuit 19 Figure 7 Low inductance grounding 21 Figure 8 Using a SureFoot adapter for grounding 22 Fi...

Страница 9: ...o a performance verification or make internal adjustments to your probe refer to the P7240 4 GHz Active Probe Service Manual Tektronix part number 071 1056 XX The manual is a printable pdf file and is...

Страница 10: ...s support 1 800 833 9200 select option 1 Service support 1 800 833 9200 select option 2 Technical support Email techsupport tektronix com 1 800 833 9200 select option 3 1 503 627 2400 6 00 a m 5 00 p...

Страница 11: ...g dense circuitry by hand fast and easy The accessory tips and adapters included enable the P7240 to be used on a wide variety of circuit architectures Figure 1 P7240 Probe featuring the TekConnect in...

Страница 12: ...l a valid TekConnect device is detected Installation The TekConnect interface features a spring loaded latch that provides audible and tactile confirmation that a reliable connection has been made to...

Страница 13: ...ser Manual 3 Options The following options are available when ordering the P7240 probe H Option D1 Calibration Data H Option C3 3 years Calibration Service H Option D3 3 years Calibration Data require...

Страница 14: ...Product Description 4 P7240 4 GHz 5X Active Probe User Manual...

Страница 15: ...e pins for direct access The ground socket provides a short ground path for high fidelity ground connections The stabilization notch permits you to use adjacent pins to reduce stresses on the probe an...

Страница 16: ...ul for probing in dense circuitry Attach the SureToe adapters the same way as the push in probe tips Do not force the tip Also be careful not to poke yourself with the sharp probe tip They can be used...

Страница 17: ...To attach the Y lead adapter gently press the lead pins into the probe head tip and ground receptacles Using the black lead for ground is recommended Three inch ground lead 3 ea Use the three inch gro...

Страница 18: ...ing information Tektronix part number 196 3482 00 package of 5 Right angle adapter Adapter spring 10 ea Use the adapter spring for low profile probing of 0 025 inch square pins The adapter spring allo...

Страница 19: ...for more information Tektronix part number 016 1772 10 package of 10 Ground pin length adapter Ground pin length adapter 10 ea The ground pin length adapter is ideal for use with signal ground pairs o...

Страница 20: ...Use the plastic box to store the probe accessories when not in use Tektronix part number 006 7164 00 Instrument case The instrument case protects the probe from harsh environments and provides room f...

Страница 21: ...eFoot tips are included with the probe and can be used with any of the socketed accessory leads SF501 The orange SureFoot tip is compatible with 50 mil JEDEC packages such as SOIC PLCC CLCC and so on...

Страница 22: ...55 ohm signal path and can be used in both single ended and differential modes Tektronix part number 679 5027 00 TekConnect interface calibration fixture The calibration fixture is required when a per...

Страница 23: ...oscillo scope 2 Set the oscilloscope to display the appropriate probe channel 3 Using a ground lead and SMT KlipChip connect the probe ground to the outer ring of the PROBE COMPENSATION connector on...

Страница 24: ...connect the probe tip from the oscilloscope and ground the probe tip Connect the KlipChip to the probe tip 7 With the probe offset set to 0 0 V the oscilloscope display should be at the ground referen...

Страница 25: ...ar range of the probe Using the offset to cancel DC signal components enables optimal probe performance See Figure 4 on page 16 for more information NOTE See your oscilloscope manual for specific inst...

Страница 26: ...used on a TekConnect interface oscilloscope the zero reference will be at the probe offset voltage 0 V 7 0 V 7 0 V 2 0 V 2 0 V 5 0 V 5 0 V Nonoperating range 30 V maximum nondestructive input voltage...

Страница 27: ...nput Voltage The P7240 is electrically protected against static voltage however applying voltages above its design limits may damage the probe tip amplifier Refer to Specifications on page 23 for the...

Страница 28: ...the probe tip and ground lead can result in a resonant circuit this circuit may cause parasitic ringing within the bandwidth of your oscilloscope Refer to Figure 5 Low inductance Ground Three inch Gro...

Страница 29: ...itance C of your probe and ground lead Calculate the approximate resonant frequency f0 at which this parasitic circuit will resonate with the following formula f0 1 2 LC The preceding equation shows t...

Страница 30: ...Operating Basics 20 P7240 4 GHz 5X Active Probe User Manual...

Страница 31: ...ground plane on top of a package being probed can minimize ground lead length and inductance See Figure 7 Figure 7 Low inductance grounding Attach a small piece of copper clad on top of the package an...

Страница 32: ...and distortion SureFoot Grounding If you cannot use the recommended low inductance grounding method you may ground the probe to the package under test using a SureFoot adapter Refer to Figure 8 Figure...

Страница 33: ...ndestructive input voltage range to the probe Table 3 Warranted electrical specifications DC Attenuation Accuracy probe only 0 2 2 excludes offset error Output Zero 10 mV or less at output of probe Ri...

Страница 34: ...with TekConnect interface DC Offset Scale Accuracy 2 of 5x actual probe gain DC Voltage Measurement Accuracy referred to input 2 of input 2 of offset 50 mV output offset 20 mV linearity error Delay Ti...

Страница 35: ...MHz 1 MHz 100 MHz 10 GHz 12 14 16 18 20 22 24 26 28 1 GHz Gain dB Gain 20 Log VOUT VIN Figure 10 Typical bandwidth 31 8 mm 1 250 in 43 8 mm 1 725 in 63 5 mm 2 500 in 91 5 mm 3 600 in 57 2 mm 2 250 in...

Страница 36: ...o 75 C 67 to 167 F The environmental exposure is the procedure stated in Tektronix Design Standard 062 2847 00 for Class 5 equipment Humidity 0 to 90 RH at 30 C to 40 C 86 to 104 _F The environmental...

Страница 37: ...libration If you need to do a performance verification or make internal adjustments to your probe refer to the P7240 4 GHz Active Probe Service Manual Tektronix part number 071 1056 XX The manual is a...

Страница 38: ...idelines 1 Use a corrugated cardboard shipping carton having inside dimensions at least one inch greater than the probe dimensions The box should have a carton test strength of at least 200 pounds 2 P...

Страница 39: ...ruments are sometimes made to accommo date improved components as they become available and to give you the benefit of the latest circuit improvements Therefore when ordering parts it is important to...

Страница 40: ...em This parts list is indented to show the relationship between items The following example is of the indentation system used in the Description column 1 2 3 4 5 Name Description Assembly and or Compo...

Страница 41: ...Figure 12 P7240 replaceable parts Fig index no Tektronix part no Serial no Effective Dscont Qty 12345 name description Mfr code Mfr part no 12 1 010 0642 00 1 PROBE FET ACT 4 GHZ 5X 1PF TDS SERIES 800...

Страница 42: ...Appendix C Replaceable Parts P7240 4 GHz 5X Active Probe User Manual 32 1 2 3 4 5 6 7 8 9 10 11 Figure 13 P7240 standard accessories...

Страница 43: ...10 1 ACCESSORY KIT GND PIN LENGTH ADAPTER PKG OF 10 80009 016 1773 10 5 016 1774 00 1 ACCESSORY KIT ADAPTER SPRING PKG OF 10 80009 016 1774 00 6 1 PROBE TIP SURETOE PACKAGE OF 4 REORDER ST501 PACKAGE...

Страница 44: ...Appendix C Replaceable Parts P7240 4 GHz 5X Active Probe User Manual 34 1 2 3 4 5 6 7 Figure 14 P7240 optional accessories...

Страница 45: ...JEDEC PKG OF 12 80009 SF502 3 SF501 1 ADPTR SUREFOOT 50 MIL JEDEC PKG OF 12 80009 SF501 4 SMK4 1 TIP PROBE MICROCKT TEST PKG OF 4 80009 SMK4 5 067 0422 00 1 CALIBRATION FIXTURE ASSY ECB TO TOP P7000...

Страница 46: ...e User Manual 36 CROSS INDEX MFR CODE NUMBER TO MANUFACTURER Mfr Code Manufacturer Address City State Zip Code 80009 TEKTRONIX INC 14150 SW KARL BRAUN DR PO BOX 500 BEAVERTON OR 97077 0001 TK0623 GENE...

Отзывы: