Operating basics
Recording and playback
You can record the workspace as a sequence of .mat
fi
les using
the Record button in the Of
fl
ine ribbon. These are recorded to
C:\Users\<user>\Documents\TekApplications\OUI\MAT Files.
You can play back the workspace from a sequence of .mat
fi
les by
fi
rst using
the Load button in the Of
fl
ine Commands section of the Home ribbon. Load a
sequence by marking the
fi
les you want to load using the Ctrl key and marking the
fi
lenames with the mouse. You can also load a contiguous series using the Shift
key and marking the
fi
rst and last
fi
lenames in the series with the mouse.
Use the Run button in the Of
fl
ine Commands section of the Home ribbon to
cycle through the .mat
fi
les you recorded. OUI uses the
fi
lter settings stored in
the .mat
fi
les.
You can override the .mat
fi
le settings with certain Analysis Parameter settings by
using the Of
fl
ine controls near the bottom of the Analysis Parameters window.
This makes it possible to reprocess the saved data using different
fi
lters or other
settings, rather than those settings stored in the .mat
fi
le. (See page 37.)
Alerts
See the Appendix for alert messages information. (See page 109,
Managing data sets with
record length > 1,000,000
It is important to break up records larger than 1,000,000 points into blocks that can
fi
t into the computer memory. This is done by setting the Blk Size to something
between 10,000 and 200,000. Typically 50,000 is a good balance between speed
of progress updates and overall processing time. When operating in this mode,
only the number of errors and other numerical measurements are maintained from
block to block. Time series information such as electric
fi
eld values and raw data
are discarded to conserve memory. This means that if you do nothing else, the
large acquisition will end with only the
fi
eld and symbol values for the last block
available along with the BER, EVM, and measurements which are collected over
the entire record. It is important in the large-acquisition case to learn how to save
intermediate data sets if the time-series data is needed.
Saving intermediate data sets: examples.
The simplest way to save intermediate
data is to record every record. (See page 52,
.) However, this
may generate a very large set of
fi
les that will then need to be analyzed later. If
you only want to save the workspace on a particular event, you can use the save
command after the CoreProcessing call.
Once you have saved the data sets, you can view them later by using the Load
command described earlier. You can load them one at a time or as a group to see a
replay. Just be sure the correct analysis parameters are being used. If you save
the entire workspace by omitting the variable names in the save statement, then
you can also open the .mat
fi
les later in MATLAB and use MATLAB plots to
examine the variables.
OM4000D Series Coherent Lightwave Signal Analyzer
53
Содержание OM4006D
Страница 1: ...xx OM4106D and OM4006D Coherent Lightwave Signal Analyzer ZZZ User Manual P071316002 071 3160 02...
Страница 2: ......
Страница 6: ......
Страница 22: ...Compliance information xvi OM4000D Series Coherent Lightwave Signal Analyzer...
Страница 24: ...Preface xviii OM4000D Series Coherent Lightwave Signal Analyzer...
Страница 100: ...Taking measurements 76 OM4000D Series Coherent Lightwave Signal Analyzer...
Страница 132: ...Appendix A MATLAB variables used by core processing 108 OM4000D Series Coherent Lightwave Signal Analyzer...
Страница 146: ...Appendix D Automatic receiver deskew 122 OM4000D Series Coherent Lightwave Signal Analyzer...
Страница 176: ...Appendix F Configuring two Tektronix 70000 series oscilloscopes 152 OM4000D Series Coherent Lightwave Signal Analyzer...
Страница 202: ...Appendix H Cleaning and maintenance 178 OM4000D Series Coherent Lightwave Signal Analyzer...
Страница 205: ...Index W Waveform averaging 48 OM4000D Series Coherent Lightwave Signal Analyzer 181...